Opportunity

The Metropolitan Water District of Southern California PlanetBids #RFB-PR-476283

MWD Solicits Ultrasonic Flow Measuring Systems Compatible with Accusonic 8510+

Posted

July 08, 2026

Respond By

August 12, 2026

Identifier

RFB-PR-476283

NAICS

334514

The Metropolitan Water District of Southern California (MWD) is seeking suppliers for new ultrasonic flow measuring systems to upgrade the Diamond Valley Lake and Skinner Water Treatment Plant facilities. - Government Buyer: - Metropolitan Water District of Southern California (MWD) - OEMs and Vendors: - Accusonic (specified as the required or compatible OEM for flowmeter consoles and transducers) - Bidders may propose 'approved equals' but must demonstrate 10+ years of continuous operation and provide references - Products/Services Requested: - Ultrasonic flowmeter transducers (internally and externally mounted, dual- and single-element) - Notable part numbers: 7658, 7634-N - Quantities: 8 external, 64 internal (across multiple locations) - Submersible HDPE-coated RG-108 transducer cables (various lengths, total quantity over 136) - Stainless steel mounting assemblies and cable penetrators - Accusonic 8510+ console compatibility required for all equipment - Installation services by manufacturer representative, including supervision and transducer location calculation - Unique/Notable Requirements: - All equipment must be compatible with the existing Accusonic 8510+ console - Bidders must provide manufacturer name, model number, and references for similar installations - Bid price must remain valid for 190 days - Manufacturer warranty of at least 24 months from installation/commissioning - Payment and performance bonds required post-award - Technical documentation, conflict of interest statement, and recent project references are mandatory - Bid submission is electronic via PlanetBids - NIGP codes include flow controllers, measuring equipment, and ultrasonic cleaners

Description

The Metropolitan Water District of Southern California is soliciting bids from qualified suppliers to provide new ultrasonic flow measuring systems that conform to specified requirements, terms, and conditions. The systems must be new, not used, and the bid price should remain valid for 190 days. Delivery is to the Robert A. Skinner Water Treatment Plant in Winchester, CA. Bidders must include a bid bond with their submission and provide manufacturer name and model number in their comments to avoid being deemed non-responsive.

View original listing