Opportunity

SAM #80NSSC26933864Q-R1

NASA Langley seeks Cryostar-compatible Liquid Nitrogen Pump 12 Replacement and Commissioning Kit

Buyer

NASA Shared Services Center

Posted

July 02, 2026

Respond By

July 09, 2026

Identifier

80NSSC26933864Q-R1

NAICS

333914

NASA Langley Research Center is seeking a fully interchangeable replacement for its Liquid Nitrogen Pump 12 (P12) used in the National Transonic Facility. - Government Buyer: - NASA Langley Research Center - OEM Highlight: - Cryostar (manufacturer of the CS400/355/20L Pump) - Products Requested: - Replacement Liquid Nitrogen Pump 12 (P12) - Must match Cryostar CS400/355/20L Pump specifications - Vertical centrifugal pump with PT100 sensor for seal leakage detection - Heating cable for thermal barrier - Grease retaining chamber with N2 purge - Close warm box with N2 purge - 2-chamber labyrinth seal - Cold box isolation plate - Electric motor LSES280SD 75kW 4 poles fixed speed 480V 60 Hz - Anticondensation heater 120V - Seal gas control panel installed and wired - Labyrinth seal low pressure drop control panel - Mechanical performance test in cryogenic conditions with liquid nitrogen - Documentation per Cryostar standard (IOM, assembly checklist, performance test report in PDF) - Commissioning Kit for Installation and Start-up - Spare parts kit for commissioning and start-up - Quantity: - 1 replacement pump - 1 commissioning kit - Unique Requirements: - Pump must be fully interchangeable with existing Cryostar CS400/355/20L Pump (Serial Number 96013/02) - Mechanical performance testing in cryogenic conditions is required - Delivery required prior to the specified deadline - Documentation must follow Cryostar standards

Description

See attachments for complete details for the RFQ, Statement of Work and Redacted Brand Name Justification.  

All correspondence should reference Notice ID 80NSSC26933864Q-R1 in the subject line.

This procurement is full and open competition.

Please include the following in your Quote:

Net 30

FOB Destination: NASA Langley Research Center

                               Central Receiving

                              4 South Marvin Street

                              Building 1206

                              Hampton, VA 23681-2199

Please provide your Cage Code & UEI # on your Quote.

Please provide ARO delivery time/Lead Time on your Quote.

If shipping is applicable, please provide on your Quote.

Please apply any discounts to your Quote.

We will not be paying with a Credit Card.

View original listing