Opportunity
SAM #36C77626R0092
VA EHRM Infrastructure Upgrades – Electrical, Mechanical, Security, and Hazardous Material Abatement at White River Junction, VT
Buyer
VA Patient Care Services
Posted
July 02, 2026
Respond By
July 24, 2026
Identifier
36C77626R0092
NAICS
236220, 238210, 238220, 562910, 238290
This opportunity from the Department of Veterans Affairs (VA) seeks comprehensive EHRM (Electronic Health Record Modernization) infrastructure upgrades at the White River Junction VA Medical Center in Vermont. - Government Buyer: - Department of Veterans Affairs, Office of Construction and Facilities Management, Veterans Health Administration, Program Contracting Activity Central (PCAC) - OEMs and Vendors Highlighted: - Eaton (UPS systems, panelboards, safety relays) - Schneider Electric (safety switches) - ASCO (power transfer switches) - Optical Cable Corporation (OCC) (fiber optic cabling) - Ortronics (cable management) - Cablofil (cable tray accessories) - DITEK (surge protectors) - LG (HVAC units) - Trane (fan coil units) - Ruskin (fire/smoke dampers) - Liebert (cooling systems) - Grundfos (water boosting pumps) - Little Giant (condensate pumps) - Vista (reverse osmosis systems) - Greenheck (exhaust fans) - HID (pivCLASS readers for access control) - Siemens (Desigo BMS digital controls) - Products/Services Requested: - Construction and demolition for EHRM upgrades - Electrical upgrades: Eaton 93PM UPS, ASCO 7000 Series transfer switches, panelboards, safety relays, surge protectors - Fiber optic cabling and connectivity: OCC cables, Ortronics racks, Cablofil accessories - Mechanical upgrades: LG HVAC units, Trane fan coils, Ruskin dampers, Liebert cooling, Grundfos pumps, Little Giant condensate pumps, Vista RO systems, Greenheck exhaust fans - Physical security: HID pivCLASS readers - Building management: Direct Digital Controls compatible with Siemens Desigo BMS - Hazardous material abatement: asbestos and lead removal - Unique/Notable Requirements: - Brand name justification for HID pivCLASS readers and Siemens-compatible controls for system compatibility and security - Extensive hazardous material abatement (asbestos, lead) required before renovation - Compliance with seismic, safety, and environmental standards - 100% set-aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB) - Detailed commissioning, warranty, and quality control procedures - Project completion required within 450 calendar days after Notice to Proceed
Description
36C77626R0092