Repair and Replacement of L7-090 PVDF Chemical Storage Tank Liner at Robins AFB

Buyer

AFSC Maintenance Contracting

Posted

July 01, 2026

Respond By

July 02, 2026

Identifier

FA857126Q0087

NAICS

238990, 332420

This opportunity is for the repair and replacement of a specialized chemical storage tank liner at Robins Air Force Base, Georgia, managed by the U.S. Air Force Sustainment Center. - Government Buyer: - U.S. Air Force, Air Force Sustainment Center, Robins Air Force Base - Offices: 402 CMXG/MXDEA (Commodities Maintenance Group) and FA8571 MAINT CONTRACTING AFSC PZIM - OEMs and Vendors: - Kynar (Arkema Inc.) is specified as the required PVDF liner material - N-FUZE (patented lining technology) is required for liner construction - No specific OEM for the liner is named, but the solicitation is single source to the OEM - Products/Services Requested: - One new L7-090 chemical storage tank liner fabricated from Kynar 2850 Flex PVDF, approx. 48" x 48" x 72" deep, with 1/4" thick sidewalls/rim and 3/8" thick bottom, using N-FUZE technology - Repair of the existing L7-090 PVDF liner, including surface preparation, fusion welding, and spark testing for leaks - Technical Data Package, status and safety reports, and EMS training deliverables - Unique/Notable Requirements: - New liner must be identical in construction, material, and instrumentation to the existing liner - Liner must be compatible with the TANKeye Plus Leak Detection System - One-year warranty on the new liner (not on repairs) - Single source procurement directed to the OEM - High priority with expedited delivery (repair within 4 weeks, new liner within 10 weeks of drawing approval) - Estimated contract value is approximately $19 million

Description

This solicitation is being conducted under Simplified Acquisition Procedures (SAP) as a Request for Quote (RFQ) No. FA857126QOO87. This requirement is being solicited as a single source requirement to the Original Equipment Manufacturer (OEM) for the repair of L7-090 Liner and purchase of one (1) additional L7-090 Liner. The Contractor shall provide all the tools, parts, materials, equipment, labor, repairs, and travel necessary to perform repairs on the existing Polyvinylidene Flouride (PVDF) L7-090 Liner for the Chemical Storage Tank in Building 20128 and supply one (1) new L7-090 Liner for the Commodities Maintenance Group (CMXG) at Robins Air Force Base (AFB), Georgia. The Contractor shall repair the existing liner in the facility inside of L7-090. The additional spare liner shall be identical in contruction, material, and instrumentation to the existing liner and be stored by CMXG for future use.

The Contractor shall provide the following: • Repair of L7-090 Liner on Tank 120 at Building 20128. This will include one (1) technician to facilitate repairs. • 1 each (PVDF) Kynar® Rigid Box Liner to fit CMXG’s existing tank • Approximately 48” x 48” x 72” deep, fabricated from ¼” thick Kynar 2850 Flex sidewalls and rim and 3/8” thick Kynar 2850 Flex bottom. Liner will be fabricated incorporating Patented (#8,133,345) N-FUZE lining technology, utilizing pressure butt-welded vertical joints and extrusion welded sidewall to bottom contruction. The tank shall have one (1) 45 degree corner where CMXG can re-install existing TANKeye Plus Leak Dectection System

Amendment 0001 corrects Period of Performance for CLIN 0002 and adjust responses due date to account for the High Priority need of this effort.