Opportunity
SAM #36C257-26-AP-2733
VA Texas Valley Coastal Bend Healthcare System Seeks Thulium Fiber Laser System for Urology Procedures
Buyer
VA Contracting Office 17
Posted
June 30, 2026
Respond By
July 06, 2026
Identifier
36C257-26-AP-2733
NAICS
339112, 334510, 423490
The Department of Veterans Affairs Texas Valley Coastal Bend Healthcare System (VATVCBHCS) is seeking information from vendors for a Thulium Fiber Laser System to support urology surgical procedures at its Harlingen, Texas facility. - Government Buyer: - Department of Veterans Affairs (VA) - Texas Valley Coastal Bend Healthcare System (VATVCBHCS), Operating Room Section of Surgical Service - Products/Services Requested: - Thulium Fiber Laser System for urology surgical procedures - Intended for soft tissue incision/ablation, prostate treatment, and management of ureteric and kidney stones - Key technical requirements: - Maximum power output: 60 Watts - Maximum frequency output: 2400 Hz - Maximum pulse energy: 6 Joules - Swivel LCD display - Emission wavelength: 1920–1960 nm - Compatibility with a full line of surgical fibers - Standard wall outlet plug-in - Air-cooled system - Includes wireless footswitch, laser cart, and safety goggles - OEMs and Vendors: - No specific OEMs or vendors are named in the notice - Unique/Notable Requirements: - System must provide faster lithotripsy with less power - Vendors must submit technical documentation, product literature, and capability statements demonstrating compliance with requirements - Estimated delivery timeframe, warranty, and contract vehicle information requested - No part numbers or purchase quantities specified
Description
THIS NOTICE IS ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES - it does not constitute a Request for Quote (RFQ)/Invitation for Bid (IFB)/Request for Proposal (RFP) or a promise to issue an RFQ, IFB or RFP in the future. This notice does not commit the VA to contract for any supply or service. Further, the VA is not seeking quotes, bids or proposals at this time and will not accept unsolicited proposals in response to this source sought notice. The VA will not pay for any information or administrative costs incurred in response to this notice. Submittals will not be returned to the responder. Not responding to this notice does not preclude participation in any future RFQ or IFB or RFP, if any is issued. If a solicitation is released, it will be synopsized on the Governmentwide Point of Entry. It is the responsibility of potential offerors to monitor the Governmentwide Point of Entry for additional information pertaining to this requirement. The anticipated NAICS code is: 339112.
General: Thulium Fiber Laser System
Description of Work: This statement of work defines the effort required for VA Texas Valley Coastal Bend Healthcare System (VATVCBHCS), Operating Room Section of Surgical Service to procure a Thulium Premium Fiber Laser System at one (1) location. The Surgical Department in Harlingen is the location requesting the procurement of a Thulium Fiber Laser to enhance the capabilities and efficiency of urology surgical procedures to include soft tissue incision/ablation and prostate treatment. Thulium Fiber Lasers are medical lasers used for ureteric and kidney stone management, flexible ureteroscope. This diagnostic and therapeutic procedure allows for minimally invasive stone management without breaking the skin barrier. It conducts procedures diagnosing and treating soft tissue conditions, including the management of benign prostate hyperplasia (BPH). The proposed Thulium Fiber Laser System will reduce liability issues and increase patient satisfaction using the newest technology and quality standards.
Place of Delivery - The vendor shall deliver the described herein to:
VATVCBHCS
VA Harlingen Healthcare Center (HCC)
Receiving Dock
2601 Veterans Drive
Harlingen, TX 78550
Product Requirements for Thulium Fiber Laser System
Thulium Fiber Laser System must provide faster lithotripsy with less power. Thulium Fiber Laser System must have a maximum power outlet of 60 Watts and a maximum frequency output of 2400 Hz, and a maximum pulse energy of 6 J.A secondary. Thulium Fiber Laser System must have a swivel LCD Display screen Thulium Fiber Laser System must operate on emission wavelengths between 1920 – 1960 nm. Thulium Fiber Laser System must be compatible with a full line of surgical fibers and provide precision cutting of soft tissue. Thulium Fiber Laser System must plug into any standard wall outlet. Thulium Fiber Laser System must be cooled by air. Thulium Fiber Laser System must include a wireless footswitch. Thulium Fiber Laser System must include a laser cart and safety goggles.
REQUESTED INFORMATION FROM INTERESTED VENDORS
Vendors responding to this notice should submit the following:
Company information (name, address, UEI, POC). Socioeconomic status (SB, WOSB, SDVOSB, 8(a), HUBZone, etc.). Capability statement addressing ability to meet requirements. Technical documentation showing how proposed equipment meets each salient characteristic. Product literature for the proposed brand name or equal device. Estimated delivery timeframe. Applicable contract vehicles (GSA, SEWP, VA FSS, etc.). Warranty information.
DISCLAIMER
This notice is not a solicitation. The Government will not pay for any information received in response to this notice and will not reimburse any costs associated with preparing or submitting responses. The results of this Sources Sought may influence the acquisition strategy for any future solicitation.