The Department of the Air Force, through the 502d Contracting Squadron at Joint Base San Antonio (JBSA) Lackland, is seeking quotations for the procurement and installation of a Honeywell Vindicator Intrusion Detection System (IDS) and Access Control System (ACS) for the Joint Electromagnetic Warfare Center (JEWC) at JBSA Lackland-Kelly Annex, Building 1003. - Government Buyer: - Department of the Air Force, 502d Contracting Squadron, Joint Electromagnetic Warfare Center, 802d Security Forces Squadron (SFS), Electronic Security Systems (ESS) - OEMs and Vendors: - Honeywell (specified as the required OEM for IDS and ACS) - Installation must be performed by Honeywell or a Honeywell Vindicator certified reseller - Products/Services Requested: - Honeywell Vindicator Intrusion Detection System (IDS), Vindicator 1500 or V5 (1 unit) - Includes keypads, control/communication panels, alarm points/devices/sensors, hardware, and software - Balanced Magnetic Switches (BMS) and Passive Infrared Sensors (PIR) for each access point - Battery backup (minimum 4 hours) - Access Control System (ACS), locally managed and compatible with Honeywell Vindicator IDS (1 unit) - Includes control computer terminal, software, card/badge printers, control and keypad panels - Magnetic Door Locks (9 units, 600 lbs rated, with emergency override) - Card/Badge Readers (2 units, single point of entry, wired for perimeter and interior doors) - Access Cards/Badges (50 units, printer compatible) - Video Management Server (VMS) with cameras - Installation services for all systems, including electrical/communication infrastructure, programming, certification testing, and warranty support - Up to 6 hours of training for staff and asset owners - Unique/Notable Requirements: - Honeywell Vindicator brand is mandatory for compatibility with the existing 802d SFS Base Defense Operations Center (BDOC) alarm system - Contractor must be Honeywell Vindicator certified - System must secure multiple rooms within a 2,610 square foot facility - Includes warranty, certification testing, and training - 100% Small Business Set-Aside - Delivery required within 90 days after receipt of order (ARO)
Description
This is a combined synopsis/solicitation for commercial products prepared in accordance with RFO part 12. This announcement constitutes only solicitation. This announcement constitutes the only solicitation; offers are being requested and a separate written solicitation will not be issued.
Solicitation number FA301626Q0073 is issued as a request for quotation (RFQ) for Honeywell Vindicator Intrusion Detection System (IDS) for the Joint Electromagnetic Warfare Center (JWEC) at Joint Base San Antonio (JBSA).
Description of Work: The Joint Electromagnetic Warfare Center at Bldg. 1003, 1301 Billy Mitchell Rd, JBSA-Lackland, San Antonio, Texas 78236, requires installation of an Access Control System (ACS) and Intrusion Detection Systems (IDS) inclusive of a Video Management Server with cameras (VMS). The Contractor shall provide all equipment and tools, necessary to provide & install a Honeywell Vindicator IDS and ACS to secure multiple rooms area at JBSA Lackland-Kelly Annex Bldg. 1003. B1003 is 2610 SF approximately (approx.); it is comprised of 2 Rooms, a high bay area, 2 restrooms, and mech room (see Statement of Work attachment 1 for additional information).
REFERENCE THE COMBO SYNOPSIS/SOLICITATION FOR INSTRUCTIONS, EVALUATIONS FACTORS, AND ITS ATTACHMENTS