Opportunity
SAM #FA460026Q0061
Procurement of 15KV Medium Voltage Cable for Offutt Air Force Base
Buyer
55th CONS Pkpl
Posted
June 25, 2026
Respond By
July 07, 2026
Identifier
FA460026Q0061
NAICS
335929, 423690
This opportunity involves the procurement of medium voltage cable for Offutt Air Force Base, managed by the 55th Contracting Squadron and 55th Civil Engineer Squadron of the U.S. Air Force. - Government Buyer: - U.S. Air Force, 55th Contracting Squadron (55 CONS PKP) and 55th Civil Engineer Squadron (55CES/CEOFE) at Offutt AFB - Products Requested: - 3,000 linear feet of #1/0 15KV 133% EPR tape shielded 220mil wire - Cable must be cut into 1,000-foot sections - Conductor: annealed uncoated copper, compact stranded (ASTM B-496) - Insulation: EPR, 133% insulation level, 220 mil thickness - Shield: 5 mil bare copper tape, helically applied with 12.5% nominal overlap - Must meet or exceed standards: ASTM, ICEA S-93-639/NEMA WC74 & S-97-682, AEIC CS8, CSA C68.10, UL 1072 - Suitable for aerial, direct burial, and underground duct installations - Rated for 15,000 V, continuous operation at 105°C, higher for emergency/short circuit - Installable without pulling lubricant - Manufacturer warranty required - OEMs and Vendors: - No specific OEMs or vendors are named in the solicitation or attachments - Unique/Notable Requirements: - Strict compliance with multiple industry standards (ASTM, ICEA, NEMA, AEIC, CSA, UL) - Cable must be delivered in specified lengths (1,000 ft cuts) - Delivery required within 60 days of award - SBA set-aside
Description
DESCRIPTION OF REQUIREMENT
Project includes, but is not limited to, the following work elements. The contractor shall furnish materials and incidentals. No alterations, additions, or deletions shall be made unless by prior approval of the government Project Manager and the government Procuring Contract Officer (PCO). The Contractor shall use SON requirements. Must be able to deliver Type MV-105 Cable is for use in aerial, direct burial, and underground duct installations as permitted by the NEC®. These cables are capable of operating continuously at a conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload conditions, and 250°C for short circuit conditions, and are rated at 15,000 V, 133% insulation level (ungrounded system). This cable may be installed without the need for pulling lubricant.
See "Attachment 1_MV Cable SON 5-11-26" for specific requirement details.
QUESTIONS DUE DATE AND TIME
Offerors are required to complete all clauses/provisions that require fill-ins and submit them with their quotes or ensure their representations and certifications are up to date in SAM.gov. Questions for solicitation are due by 30 June 2026 at 10:00 AM CDT.
OFFER DUE DATE AND TIME
Tuesday, 7 July 2026 at 12:00 PM CDT.
CONTRACTING OFFICE CONTACT INFORMATION
All offers and questions pertaining to this solicitation shall be sent by email to: SrA Robert Armstrong at robert.armstrong.23@us.af.mil Mrs. Nichole Barragan at nichole.barragan.2@us.af.mil