Opportunity

SAM #75N98026R00105

Market Survey for Nikon AX R with Nikon Spatial Array Confocal Microscope System or Equal

Buyer

NICHD

Posted

June 17, 2026

Respond By

June 24, 2026

Identifier

75N98026R00105

NAICS

334516, 333316, 339112, 423490

The National Institutes of Health (NIH), Office of the Director (OD), National Institute of Child Health and Human Development (NICHD), is conducting a market survey for a confocal imaging system. - Government Buyer: - National Institutes of Health (NIH) - Office of the Director (OD) - National Institute of Child Health and Human Development (NICHD) - OEM Highlight: - Nikon - Requested Product: - Confocal imaging system: Nikon AX R with Nikon Spatial Array Confocal (NSPARC) Microscope Detector Technology System or equal - No specific part numbers or quantities provided - Key Technical Requirements: - Upright microscope configuration (FN1 compatible) - 25-element SPPC array detector with single-photon sensitivity and ultra-low-noise - Improved signal-to-noise ratio - Compatibility with high-numerical-aperture water-dipping objectives - Patch-clamp integration and live pharmacological manipulation - Time-lapse, calcium, neurotransmitter, voltage, and low-light imaging - Photobleaching and phototoxicity reduction - Super-resolution lateral (100 nm) and axial (300 nm) capabilities - AX R resonant scanner compatibility, high-speed acquisition (up to 720 fps) - Large field of view (FN25 optical system) - Nikon NIS-Elements software compatibility - Workflow compatibility with existing Nikon systems - Respondent Requirements: - Demonstrate capability to meet all technical specifications - Provide descriptive literature, delivery timeframe, and warranty information - No administrative or procedural requirements included

Description

The National Institutes of Health (NIH), Office of the Director (OD) is conducting a market survey to determine the availability and technical capability of qualified small businesses, including 8(a) small businesses, small, disadvantaged businesses, woman-owned small businesses, service-disabled veteran-owned small businesses or HUBZone small businesses capable of providing  a new Brand name or equal to Nikon AX R with Nikon Spatial Array Confocal (NSPARC) Microscope Detector Technology System.

Description:

Planned experiments involve ex vivo imaging of dissected mouse cochleae to study dendritic function and signaling in olivocochlear efferent neurons. Experiments will include calcium imaging, neurotransmitter imaging, genetically encoded voltage indicator imaging, and simultaneous patch-clamp electrophysiology. The neuronal dendrites under study are approximately 1 µm in diameter, produce dim fluorescent signals, and require high-speed imaging with high signal-to-noise ratio. 

The microscope system must provide enhanced fluorescence detection sensitivity to enable reliable detection of weak fluorescent signals while minimizing photobleaching and phototoxicity. The system must be configured as an upright microscope to accommodate ex vivo cochlear preparations, high-numerical-aperture water-dipping objectives, live pharmacological manipulations during experiments, and integration with patch-clamp electrophysiology equipment. 

Product Specifications/Features/Salient Characteristics Required Minimum Specifications:

Required Specifications for Confocal Imaging System:

Microscope configuration  -Upright microscope configuration (FN1 compatible) 

Detector technology  -25-element SPPC (Single Pixel Photon Counter) array detector 

Detector sensitivity - Single-photon sensitivity 

Detector noise  - Ultra-low-noise detector array 

Signal-to-noise ratio  - Improved SNR compared with conventional PMT and GaAsP detectors 

Imaging application  - Live imaging of ex vivo cochlear preparations 

Objectives  -Compatible with high-numerical-aperture (1.0 N.A.) water-dipping objectives 

Patch-clamp integration  -Compatible with simultaneous electrophysiology experiments 

Drug application  -Supports live pharmacological manipulation during imaging 

Time-lapse imaging  -Required for monitoring dynamic neuronal activity 

Calcium imaging  -Required 

Neurotransmitter imaging  -Required 

Voltage imaging  -Required 

Low-light imaging -  Required for dim genetically encoded indicators 

Photobleaching reduction  - Improved signal collection allowing lower excitation power 

Phototoxicity reduction  -Required for extended live imaging experiments 

Lateral resolution  -Approximately 100 nm super-resolution capability 

Axial resolution  - Approximately 300 nm super-resolution capability 

Resonant imaging  -Compatible with AX R resonant scanner 

Pixel dwell time  -As short as 200 nanoseconds 

Maximum resonant image size  - Up to 2048 × 2048 pixels 

High-speed acquisition  - Up to 720 fps at 2048 × 16 pixels 

Large field of view  -FN25 optical system 

Software compatibility  -Nikon NIS-Elements software compatibility required 

Existing workflow compatibility  -Compatible with existing Nikon imaging workflows and user expertise 

User training burden  - No significant additional training compared to existing Nikon systems 

Collaborative research support  - Capable of supporting NIH and extramural collaborations 

Interested firms with the capability of providing all the required items shall submit a capability statement to assist the Government in determining in accordance with the Federal Acquisition Regulation 19.104-1.

The intended procurement will be classified under North American Industrial Classification (NAICS) code 334516 with a size standard of 1000e.  All respondents are required to identify their firm’s size and type of business.  Interested firms responding to this market survey must provide (a) capability statement demonstrating their experience, skills and capability to fulfill the Government’s requirements for the above. The capability statement shall be in sufficient enough details so that the Government can determine the experience and capability of your firm to provide the items above.    Offers must also be accompanied by descriptive literature, delivery timeframe, warranties and other information that demonstrates that the offer meets all the foregoing requirements. Capability statements must include the name and telephone number, and email address of a point of contact having authority and knowledge to discuss responses with Government representatives.  Capability statements in response to the market survey that do not provide sufficient information for evaluation will be considered non-responsive.  A copy of the capability statement must be received via email to robinsti@mail.nih.gov  Attn: Tina Robinson prior to 5:00 pm eastern daylight time on June 24, 2026.  Capability statement must reference solicitation#   75N98026R00105.  Submission by email must also reference solicitation # 75N98026R00105 on the subject line of the email. Any questions must be sent via email to robinsti@mail.nih.gov and must include solicitation# 75N98026R00105 on the subject line of email. Capability statements, etc will not be returned to firm/sender.  This synopsis is for information and planning purposes and is not to be construed as a commitment by the Government, nor will the Government pay for information solicited.  

View original listing