Opportunity
SAM #W912p526TKDB4
Eaton Vacuum Circuit Breaker Refurbishment for USACE Nashville District Power Plants
Buyer
Nashville District, USACE
Posted
June 17, 2026
Respond By
June 24, 2026
Identifier
W912p526TKDB4
NAICS
335313, 335999, 238210
The US Army Corps of Engineers, Nashville District, is seeking information from qualified contractors for the refurbishment and delivery of Eaton vacuum circuit breakers at three power plants. - Government Buyer: - US Army Corps of Engineers, Nashville District (ENDIST NASHVILLE) - OEMs and Vendors: - Eaton (Original Equipment Manufacturer) - Products/Services Requested: - Refurbishment and delivery of three Eaton 150VCP-WG-50-3000A Vacuum Circuit Breakers (VCB) - Part Number: 150VCP-WG-50-3000A - Quantity: 3 - Service must use Eaton-approved test equipment - Refurbished VCBs must be compatible with existing USACE switchgear - Unique or Notable Requirements: - Respondents must indicate if they are a Certified Eaton Repair Facility - Contractors must provide information on relevant past projects and business classification under NAICS 238210 - All labor, tools, materials, and plant necessary for refurbishment and delivery must be furnished by the contractor
Description
REQUEST FOR INFORMATION
The Government is issuing this Request for Information to determine a competitive basis for the procurement described. This is not a solicitation. No reimbursement will be made for any costs associated with providing information in response to this survey.
This survey is for market research purposes only. Only contractors capable of performing this type of work should respond to this Request for Information.
Requirement: The work shall consist of furnishing all labor, tools, materials, and Eaton approved test equipment necessary to refurbish and deliver a total of three (3) total Eaton 150VCP-WG-50-3000A Vacuum Circuit Breakers (VCB), property of the US Government, to Cordell Hull, Wolf Creek, and Old Hickory respectively. The VCBs have been provided to Eaton for evaluation and recommended refurbishment. Following final refurbishment, the contractor shall return three (3) Eaton 150VCP-WG50-3000A VCB to Cordell Hull Power Plant, Wolf Creek Power Plant, and Old Hickory Power Plant as described below. The breaker must be compatible with existing USACE switchgear.
The contractor will be required to provide all plant, labor and materials to complete the project.
PSC Z1MD Maintenance of EPG Facilities - Hydro NAICS 238210 Electrical Contractors and Other Wiring Installation Contractors, Size Standard $19M.
Survey: The Government is issuing this notice to determine a competitive basis. This is not a solicitation and the items listed herein are subject to change or eliminated from the requirement. This survey is for market research purposes only. Only contractors capable of performing this type of work should respond to this Request for Information.
Your response to this survey is requested by 1:00 PM Central Time Wednesday, June 24, 2026. Please send by email to Kerri Broglin at Kerri.D.Broglin@usace.army.mil
Name of your firm:
CAGE:
Point of Contact, Phone number and EMAIL address:
Are you a Certified Eaton Repair Facility:
Please provide responses to the following:
1) List three (3) projects completed within ten (10) years of the date of this notice that demonstrates experience, as a prime contractor or subcontractor, constructing gantry cranes with capacities exceeding 100 tons.
(a) Project Name:
Contract Number (if applicable):
Year Completed:
Prime Contractor or Sub-Contractor:
Type and percentage of work self-performed (based on contract value):
Dollar Amount:
General Description of project:
(b) Project Name:
Contract Number (if applicable):
Year Completed:
Prime Contractor or Sub-Contractor:
Type and percentage of work self-performed (based on contract value):
Dollar Amount:
General Description of project:
(c) Project Name:
Contract Number (if applicable):
Year Completed:
Prime Contractor or Sub-Contractor:
Type and percentage of work self-performed (based on contract value):
Dollar Amount:
General Description of project:
Are you a Small Business classified under the above NAICS code? If so, do you fall into a sub-category (e.g. HubZone, 8(a), SDVOSB, WOSB, etc.)?
If this requirement is advertised, do you anticipate submitting a quote?
Please provide any additional information you feel is necessary: