CSC Solicits Replacement of Over 1,100 Fire Sprinkler Heads at Matsqui and Fraser Valley Institutions

Posted

June 15, 2026

Respond By

July 20, 2026

Identifier

21807-26-0046

NAICS

238290

Correctional Service Canada (CSC) is seeking competitive bids for the replacement of expired fire sprinkler heads at Matsqui and Fraser Valley Institutions in Abbotsford, British Columbia. - Government Buyer: - Correctional Service Canada (CSC), Pacific Region - OEMs and Vendors Mentioned: - Grinnell (Duraspeed, Duraspec) - Central (GB4 804a, 804A, G3101, 66h3) - Tyco (TY3131, TY3331) - Glove (GL5501) - Star (PH-5 S2046, SG SSU 722A, SSP 722A) - Rasco (F1FR R3615, SSU F1FR R3625) - Victaulic (V3610) - VK/Viking (VK300) - V2708 (SSP) - Products/Services Requested: - Supply and installation of over 1,100 new fire sprinkler heads of various models and types (upright, pendant, sidewall, concealed, tamper-proof) - Notable quantities include: - 512 Grinnell Duraspec SSU2 upright heads - 195 Grinnell Duraspeed upright heads - 56 VK300 upright heads - 55 Star PH-5 S2046 tamper-proof sidewall heads - All replacements must match or be equivalent to the specified models and comply with NFPA 13 and 25 fire protection standards - Provision of spare heads for storage as per NFPA 13 - Installation, testing, and restoration of the fire suppression system - Submission of manufacturer’s shop drawings/specifications for each type of sprinkler head replaced - Use of equipment such as a Dropmaster™ vacuum system (or equivalent) to prevent spills/drips during installation - Unique/Notable Requirements: - Strict compliance with institutional security and safety policies - All work must be completed within 34 weeks of contract acceptance - Open only to Canadian suppliers and those from applicable trading partners - Selection based on lowest price

Description

The Correctional Service of Canada, Pacific Region requires the replacement of sprinkler heads at Matsqui and Fraser Valley Institution. The work involves replacing expired sprinkler heads with the same or equivalent make and model to ensure fire suppression continuity according to NFPA 13 standards. The contractor must provide and install new sprinkler heads, use equipment such as a Dropmaster™ vacuum system to maintain vacuum and prevent spills, and submit manufacturer’s shop drawings/specifications for each sprinkler head replaced. The contract duration is 9 months, and the procurement method is competitive open bidding with selection based on the lowest price.

View original listing