Opportunity
SAM #140FS126Q0118
Environmental Investigation and Remediation Services for Suspected Underground Storage Tank at Yukon Flats NWR School Site
Buyer
USFWS Satellite Tracking Team 1
Posted
June 16, 2026
Respond By
June 29, 2026
Identifier
140FS126Q0118
NAICS
562910, 541620
This opportunity from the U.S. Fish and Wildlife Service seeks environmental investigation and remediation services for a suspected underground storage tank (UST) at the Beaver, Alaska BIA School site within the Yukon Flats National Wildlife Refuge. - Government Buyer: - U.S. Fish and Wildlife Service, Legacy Region 7 Alaska - FWS SAT Team 1, Falls Church, VA - Yukon Flats National Wildlife Refuge - Scope of Work: - Survey suspected UST area using ground penetrating radar (GPR), magnetometers, and electromagnetic (EM) conductivity, with GPS mapping - If UST is confirmed: - Conduct bore scope evaluation of fill tube - Perform soil and groundwater sampling and laboratory analysis for Diesel Range Organics (DRO), Gasoline Range Organics (GRO), BTEX, PAHs, and VOCs per Alaska Department of Environmental Conservation (ADEC) protocols - Prepare site characterization and corrective action reports, including remediation recommendations and cost proposals - Coordination for transportation and permits due to remote location - Products/Services Requested: - Underground Storage Tank Investigation and GPR/EM Survey (Part Numbers: 0001, 00010) - Bore Scope Evaluation, Soil and Groundwater Investigation, Sampling, Laboratory Analysis, ADEC Coordination, and Reporting (Part Numbers: 0002, 00020) - Additional Soil Samples (Part Numbers: 0003, 00030) - Additional Groundwater Samples (Part Numbers: 0004, 00040) - Quantities: - Main investigation and survey: 1 - Bore scope and environmental investigation (option): 1 - Additional soil samples: 1 (option, per sample) - Additional groundwater samples: 1 (option, per sample) - Unique Requirements: - Vendors must be Alaskan qualified environmental professionals meeting 18 AAC 75.33 - Demonstrated experience with GPR/EM surveys and contaminated site investigations - Compliance with ADEC protocols for sampling and reporting - All work must be completed by November 30, 2026 - Set aside 100% for small businesses under NAICS 562910 Remediation Services - OEMs and Vendors: - No specific OEMs or product manufacturers are named; services rely on specialized environmental equipment (GPR, EM, bore scope, laboratory analysis) - Period of Performance: - Work to be completed by November 30, 2026, with initial deliverables due within 10 workdays after pre-work meeting and review periods up to 45 workdays for government and ADEC comments - Potential Competitors: - Environmental consulting firms with Alaska qualifications and contaminated site investigation experience - Companies offering GPR, EM, and laboratory analysis services - Estimated Contract Value: - Likely range: $100,000 to $350,000, based on scope and remote logistics
Description
YKF NWR - School Underground Storage Tank Assessment This project is to confirm if this is an undocumented underground storage tank that has not been properly assessed and removed. This project will use ground penetrating radar to detect if a tank is present. If a tank is present, than additional testing of soil and groundwater will be conducted to determine if Diesel Regulated Organic (DRO) contamination is present.