Opportunity

Cedar Rapids Ionwave #PUR0526-326

As-Needed Door Replacement and Repair Services for Water Pollution Control Facility

Posted

June 08, 2026

Respond By

June 19, 2026

Identifier

PUR0526-326

NAICS

238290, 238390

This opportunity seeks qualified contractors for as-needed door repair and replacement at the City of Cedar Rapids Water Pollution Control Facility (WPC): - Government Buyer: - City of Cedar Rapids, Water Pollution Control Facility - Products Requested: - Exterior metal insulated doors (corrosion-resistant) - Interior hollow metal doors - Fiberglass reinforced polymer (FRP) doors for high-moisture areas - Fire-rated doors and frames (code-compliant) - Access doors for mechanical/electrical rooms - Double doors and oversized equipment access doors - Security doors with panic hardware - Commercial-grade hardware (continuous hinges, panic hardware, locksets, door closers, kick plates, corrosion-resistant fasteners) - Services Requested: - Removal and disposal of existing doors, frames, and hardware - Installation, finishing, and restoration of new doors and hardware - Testing and commissioning (including fire-rated assemblies) - Safety training and site coordination (OSHA 10 certification required) - Unique/Notable Requirements: - All doors and hardware must meet ASTM, ANSI, and NFPA standards - Contractors must provide OSHA 10 certified employees - Safety orientation and access badges required for all personnel - Work must be coordinated to minimize disruption to plant operations - No specific OEMs, part numbers, or quantities are specified; vendors must supply corrosion-resistant, commercial-grade products meeting the described standards.

Description

The City of Cedar Rapids Utilities Department is soliciting sealed bids for furnishing, removing, and replacing interior and exterior doors of various sizes and types at the Water Pollution Control Facility (WPC). The project includes coordination, demolition, installation, finishing, and restoration to ensure all doors meet operational, safety, corrosion resistance, and security requirements typical of wastewater treatment environments. Contractors must field-verify all door openings and conditions prior to fabrication or installation and comply with applicable building codes, OSHA requirements, and facility standards. The work also involves providing commercial-grade hardware, replacing damaged frames, and ensuring minimal disruption to plant operations during installation.

View original listing