This opportunity is for a design-build contractor to repair and replace the roof of Building 10571 at Joint Base Elmendorf-Richardson (JBER), Alaska, managed by the U.S. Air Force 673D Civil Engineer Squadron. - Government Buyer: - U.S. Air Force, 673D Civil Engineer Squadron (673 CES/CENM), Joint Base Elmendorf-Richardson, Alaska - Products and Services Requested: - Removal of existing built-up roof (BUR) from both barrel and lean-to roof sections - Installation of new 3-ply SBS-Modified BUR roof assembly with granular cap sheet on the barrel roof - Installation of three new 90-mil EPDM roof assemblies (fully adhered) on lean-to sections - Replacement of roof drains, overflow drains, vent pipes, flashings, curbing, parapet walls, metal copings, trim, insulation, vapor barrier, cant strips, cover board, and expansion joints - Installation of steel ribbed siding, drip edge, and stainless steel parapet coping cap - Installation of flexible horizontal lifeline fall protection systems (2 units), including operator training and certification - Design and engineering services with phased design package submissions (65%, 95%, 100%) - Quality control and construction management services - Unique or Notable Requirements: - Building 10571 is a historic, one-story, 68,986 SF facility constructed in the early 1940s; compliance with historic preservation and local codes is required - Roofing systems must include a 25-year warranty - Fall protection systems must comply with OSHA and ANSI standards, designed for two simultaneous users - Coordination with airfield management and adherence to controlled area security - Daily reporting and project status meetings required - Project must avoid interference with the Arctic Thunder Open House event - No specific OEMs or part numbers are listed, but Smith or Zurn Z-100 Series roof drains (or approved equal) are referenced as acceptable products - The procurement is a Total Small Business Set-Aside
Description
Site Visit is scheduled for 8 June at 1:00PM (Local Time). Building 10571 is a one-story, 68986 square feet (SF) building framed from steel and cast concrete (beams and columns with CMU infill). The building was originally constructed in the early 1940s and is a historic property. The main open space is 200-ft by 229 ft with a high barrel roof section that’s approximately 50,000 SF. Additionally, there are three (3) low slope roof lean-to sections. The North lean-to section is approximately 36-ft by 268-ft, with the South lean-to section at approximately 36-ft by 229-ft. The West lean-to section is approximately 36-ft by 180-ft. This Design-Build project will remove the existing built-up roof (BUR) from both barrel center section and the three (3) lower roof lean-to sections down to the existing structural decking. New 3-ply SBS-Modified BUR roof assembly with granular cap sheet on the barrel roof section shall be installed and the three (3) lower roof lean-to sections shall be replaced with new 90-mil Ethylene Propylene Diene Monomer (EPDM) roof assemblies. All roofing assemblies shall be fully adhered. Replace existing roof drains, flashings, vent pipe flashing, cover board, insulation, vapor barrier, cant strips, metal copings and trim with new.