Opportunity

PIEE #FA500026Q0025

Hangar Roof Repair and Replacement at JBER, Alaska (Building 11525)

Buyer

673d CONS LGC

Posted

May 27, 2026

Respond By

June 26, 2026

Identifier

FA500026Q0025

NAICS

238160

The U.S. Air Force at Joint Base Elmendorf-Richardson (JBER), Alaska, is seeking small business contractors for the repair and replacement of the roof on historic Hangar Building 11525. - Government Buyer: - Department of the Air Force, 673rd Civil Engineer Squadron, 673 CONS LGC - Contracting officer: Robin Cole-Barden - Scope of Work: - Remove existing built-up roof (BUR) systems from both the barrel center and east side low roof sections - Install new fully adhered 3-ply SBS-Modified BUR roof assembly with granular cap sheet on the barrel roof section - Install new 90-mil EPDM roof assembly on the south lower roof section - Replace roof drains, flashings, vent pipe flashing, cover board (as required), vapor barrier, cant strips, metal copings, and trim - Provide all labor, materials, equipment, tools, transportation, and supervision - Products/Services Requested: - Hangar roof repair and replacement services for Building 11525 (Project FXSB 26-6837) - No specific OEMs, brands, or part numbers are specified - Notable Requirements: - The building is historic and one-story, approximately 113,000 square feet - 100% Small Business Set-Aside under NAICS 238160 - Firm-fixed-price contract - Performance period is 730 calendar days after notice to proceed - Locations: - All work to be performed at Joint Base Elmendorf-Richardson (JBER), Alaska - Inspection and acceptance at JBER, with specific addresses provided

Description

Site visit is scheduled for 8 June, 2026, at 12:00PM. Building 11525 is a one-story, 113,000 square feet (SF) building framed from steel and cast concrete (beams and columns with CMU infill). The building was originally constructed in the early 1940s and is a historic property. The high barrel roof section that’s approximately 200-ft (curved) by 280-ft, two low roof low sections that are approximately 35-ft by 280-ft each, and one low roof section that approximately 62 ft by 242 ft. This project will remove the existing built-up roof (BUR) from both barrel center section and the east side roof low section identified in Sheets AD-101 and A-101, down to the existing decking and replaced with new 3-ply SBS-Modified BUR roof assembly with granular cap sheet on the barrel roof section and the south lower roof low section shall be replaced with a new 90-mil Ethylene Propylene Diene Monomer (EPDM) roof assembly. All roofing assemblies shall be fully adhered. Replace existing roof drains, flashings, vent pipe flashing, cover board (as required), vapor barrier, cant strips, metal copings and trim with new.

View original listing