Opportunity
SAM #FA500026Q0024
Design-Build Roof Repair and Replacement at JBER Building 10571
Buyer
673d CONS LGC
Posted
May 27, 2026
Respond By
June 26, 2026
Identifier
FA500026Q0024
NAICS
238160
This opportunity involves a design-build roof repair and replacement project at Joint Base Elmendorf-Richardson (JBER), Alaska. - Government Buyer: - Department of Defense, Department of the Air Force, Pacific Air Forces - 673d Contracting Squadron (FA5000 673 CONS LGC) - Scope of Work: - Remove existing built-up roof (BUR) from both the barrel center section and three lower lean-to roof sections of Building 10571 - Install new 3-ply SBS-Modified BUR roof assembly with granular cap sheet on the barrel roof section - Install new 90-mil EPDM roof assemblies on the three lower lean-to sections - All roofing assemblies must be fully adhered - Replace existing roof drains, flashings, vent pipe flashing, cover board, insulation, vapor barrier, cant strips, metal copings, and trim with new materials - Products/Services Requested: - Design-build roof repair and replacement services - No specific OEMs, vendors, or part numbers are identified - Unique/Notable Requirements: - Use of 3-ply SBS-Modified BUR and 90-mil EPDM roofing systems - Complete removal down to existing structural decking - Full replacement of all associated roofing components - Place of Performance: - Building 10571, Joint Base Elmendorf-Richardson, Alaska
Description
Site Visit is scheduled for 8 June at 1:00PM (Local Time). Building 10571 is a one-story, 68986 square feet (SF) building framed from steel and cast concrete (beams and columns with CMU infill). The building was originally constructed in the early 1940s and is a historic property. The main open space is 200-ft by 229 ft with a high barrel roof section that?s approximately 50,000 SF. Additionally, there are three (3) low slope roof lean-to sections. The North lean-to section is approximately 36-ft by 268-ft, with the South lean-to section at approximately 36-ft by 229-ft. The West lean-to section is approximately 36-ft by 180-ft. This Design-Build project will remove the existing built-up roof (BUR) from both barrel center section and the three (3) lower roof lean-to sections down to the existing structural decking. New 3-ply SBS-Modified BUR roof assembly with granular cap sheet on the barrel roof section shall be installed and the three (3) lower roof lean-to sections shall be replaced with new 90-mil Ethylene Propylene Diene Monomer (EPDM) roof assemblies. All roofing assemblies shall be fully adhered. Replace existing roof drains, flashings, vent pipe flashing, cover board, insulation, vapor barrier, cant strips, metal copings and trim with new. Additional Links:Department of Defense Procurement ToolboxPIEE Solicitation Module Link for FA500026Q0024Registration Instructions for the PIEE Solicitation ModuleWeb Based Training for the PIEE Solicitation Module