Opportunity
SAM #BSA475591
Low-Temperature Scanning Probe Microscope Integration for Brookhaven National Laboratory
Buyer
Brookhaven National Laboratory
Posted
May 22, 2026
Respond By
June 23, 2026
Identifier
BSA475591
NAICS
334516, 334519, 541715
Brookhaven National Laboratory, managed by Brookhaven Science Associates under the Department of Energy, is seeking a contractor to design, fabricate, and integrate a Low-Temperature Scanning Probe Microscope (LT-SPM) into its Multiprobe UHV Surface Analysis System at the Center for Functional Nanomaterials. - Government Buyer: - United States Department of Energy - Brookhaven Science Associates, LLC - Procurement and Property Management Division - OEMs and Vendors: - Scienta Omicron (for MATRIX SPM controller compatibility) - Products/Services Requested: - Low-Temperature Scanning Probe Microscope (LT-SPM) chamber (custom-designed UHV chamber with sample-transfer wobble stick, storage carousel, and multiple ports) - SPM scanner and sample stage (with seven additional electrical contacts, removable magnetic field assembly, internal electronics including STM and AFM preamplifiers, heaters, temperature sensors, and wiring) - Modified radiation shield box (liquid-nitrogen shield with optical and effusion cell access, adjustable eddy-current damping) - Custom high-frequency and specialized cables (for STM, AFM, heating, thermocouple, and PPMS, ~10 meters each) - LHe preamplifier with power converter (P/N 1032049, includes power converter P/N 1032550 and UHV cabling/feedthrough P/N 1032552) - Fabrication, installation, and testing of LT-STM/QPlus AFM system - Services: - On-site installation and integration of SPM components on the cryostat (7 units) - Performance testing and atomic-resolution verification on Au(111) or graphite crystals - Unique/Notable Requirements: - System must achieve atomic resolution STM and AFM at ~5 K - Must support electrical transport measurements - Full compatibility with existing cryostat and Scienta Omicron MATRIX SPM controller - Supplier to collaborate with CFN staff for chamber design and integration - Quality assurance and corrective action if performance issues arise - Delivery and installation at Brookhaven National Laboratory - Place of Performance/Delivery: - Brookhaven National Laboratory, Upton, NY (98 Rochester Street and P.O. Box 5000, 11973)
Description
BSA is procuring the Integration of a Low-Temperature SPM into a Multiprobe UHV Surface Analysis System. The requirement form and/or function supports the design and development of a lowtemperature scanning probe microscope (LT-SPM) and its integration into the existing multiprobe system without compromising or sacrificing any original system functionality. The LT-SPM will include a new SPM scanner, a sample stage with seven additional electrical contacts, a removable magnetic field assembly, required internal electronics, and all necessary wiring and cabling, while utilizing an existing cryostat previously purchased from the same Supplier for a prior LT-STM system. All SPM cabling will be compatible with the existing Scienta Omicron MATRIX SPM controller. In addition, A UHV SPM chamber will be designed and built by the Supplier in close collaboration with CFN staff to ensure full compatibility with the existing multiprobe system, enabling smooth sample and STM tip transfer between chambers and reliable SPM operation under UHV conditions. The Supplier will install all new components within the cryostat at CFN, including internal electronics, wiring, and cabling, and will perform system performance and quality tests on an Au(111) crystal or graphite surface to demonstrate atomic resolution for both STM and AFM.