Opportunity
SAM #1331L526NTIAGener
Generac 50kW Backup Generator Purchase and Installation for Table Mountain Test Site
Buyer
Department of Commerce
Posted
May 20, 2026
Respond By
June 04, 2026
Identifier
1331L526NTIAGener
NAICS
238210, 238290
The Department of Commerce, through its Office of Acquisition Management and the Institute for Telecommunication Sciences (ITS), is seeking quotations for the purchase and installation of a Generac SG050NA 50kW gaseous backup generator at the Table Mountain Advanced Communications Test Site in Longmont, Colorado. - Government Buyer: - Department of Commerce, Office of Acquisition Management (OAM-SSPO) - National Telecommunications and Information Administration (NTIA), Institute for Telecommunication Sciences (ITS) - OEM Highlight: - Generac is the specified Original Equipment Manufacturer (OEM) for the generator - Vendors: - No specific resellers or integrators are named; procurement is a 100% small business set-aside - Products Requested: - Generac SG050NA 50kW gaseous backup generator (Part Number: SG050NA), 1 unit - TX Series 200 Amp, 3 Pole Transfer Switch, 1 unit - MLCB 125 Amp Thermal-Magnetic Breaker, 1 unit - Power Zone Pro Digital Control Panel, 1 unit - 110 AH, 925 CCA Group 31 Battery with charger, block heater, and heating pad, 1 unit - Critical Grade Silencer and Exhaust Piping, 1 unit - 8 Function Alarm Relay Panel, 1 unit - 21 Light Remote Annunciator, 1 unit - Remote Emergency Stop Switch, 1 unit - Services Requested: - Site survey and preparation, including code compliance and load study - Concrete pad installation and mounting - Generator installation, wiring, and fuel line connections - Electrical connections and control panel integration - Transfer switch installation and commissioning - Battery and heating system setup - Exhaust and silencer system installation - Alarm and remote monitoring setup - Final inspection, testing, and commissioning - Unique/Notable Requirements: - Generator must be Generac SG050NA, 50kW, gaseous, with 4.5L spark-ignited engine and Powerzone controller - Installation must comply with NFPA 99/110, UL 6200, and seismic standards - Includes transfer switch, battery system, silencer, alarm/monitoring, and emergency stop - All work to be performed at the Table Mountain Advanced Communications Test Site, with specific delivery and installation at building I10C and other federal facility locations - Place of Performance: - Table Mountain Advanced Communications Test Site, Longmont, Colorado (including building I10C and other ITS facilities) - Delivery access via 8600 N. 39th Street, Longmont, CO 80503
Description
PURCHASE AND INSTALL GENERATOR