Turn-key Installation of Electrical Circuits and Outlets in Dormitories at Seymour Johnson AFB
Buyer
4th Consolidated Squadron, ACC
Posted
May 05, 2026
Respond By
May 18, 2026
Identifier
FA480926Q0030
NAICS
238210
This opportunity involves the U.S. Air Force's requirement for a turn-key installation of new electrical circuits and outlets in eight unaccompanied military housing dormitories at Seymour Johnson Air Force Base, North Carolina. - Government Buyer: - U.S. Air Force, 4th Contracting Squadron, Seymour Johnson Air Force Base - Scope of Work: - Turn-key installation of new 20-amp, 120-volt GFCI-protected electrical circuits - Installation of a total of sixteen new 20-amp single-pole GFCI circuit breakers (compatible with Siemens bolt-on panels) - Installation of sixty-four new 15-amp duplex receptacles (four per stairwell, eight buildings) - Installation of approximately 2,900 linear feet of 3/4" Schedule 40 PVC conduit and over 8,600 feet of #12 THWN-THHN copper wire - Use of GFCI-compatible weatherproof "in-use" covers - All work must comply with the latest National Electrical Code (NEC), UFC 3-501-01, and UFC 3-520-01 - Coordination with government POC to minimize resident disruption - OEMs and Vendors: - Siemens (circuit breakers must be compatible with Siemens panels) - Notable Requirements: - All materials, labor, and equipment to be provided by the contractor - Work to be completed on a building-by-building basis, with each building's work finished within ten days of commencement - Strict compliance with federal and military electrical standards - Locations: - Seymour Johnson Air Force Base, Goldsboro, NC (multiple dormitory buildings) - Inspection and acceptance at specified base addresses
Description
This requirement is for the complete turn-key installation of new electrical circuits and outlets at eight (8) Unaccompanied Military Housing (dormitory) buildings at Seymour Johnson Air Force Base (SJAFB), North Carolina. The service will provide dedicated, accessible power to the ground-floor stairwells (East and West ends) of each facility.
The scope requires the contractor to furnish all labor, materials, and equipment to install sixteen (16) new 20-amp, 120-volt Ground Fault Circuit Interrupter (GFCI) circuits. These circuits will power a total of sixty-four (64) new 15-amp duplex receptacles, with four receptacles per stairwell. Key materials include approximately 2,900 linear feet of 3/4" Schedule 40 PVC conduit, over 8,600 feet of #12 THWN-THHN copper wire, GFCI-compatible weatherproof "in-use" covers, and 20-amp single-pole, bolt-on GFCI circuit breakers compatible with the existing Siemens electrical panels.
All work, materials, and labeling shall conform to the most current editions of the National Electrical Code (NEC), UFC 3-501-01, and UFC 3-520-01.