Opportunity

SAM #SP4706-26-Q-00XX

DLA Columbus Solicitation for 3 Phase Power Supply Test Systems and Accessories

Buyer

DLA Energy Columbus Division

Posted

May 05, 2026

Respond By

May 16, 2026

Identifier

SP4706-26-Q-00XX

NAICS

334516, 334515, 541380, 335999

This opportunity from the Defense Logistics Agency (DLA) Columbus requests advanced power supply test systems for its Product Test Center. - Government Buyer: - Defense Logistics Agency (DLA), DCSO-COLUMBUS-DIVISION-2 - Delivery to Defense Supply Center Columbus (DSCC), Ohio - Products Requested: - 18kVA 3 Phase Power Supply Test System (1 unit) - 1kVA 3 Phase Power Supply Test System (1 unit) - Both systems must supply DC, single-phase, and three-phase power from DC to 5kHz - NIST Traceable and ISO 17025 accredited calibration certificates required - All necessary cables, accessories, and wheeled frames included - Two Windows 11 PCs with peripherals, hardware, ports, software, and permanent licenses for system control - GPIB, ethernet, and USB interfaces for connectivity - Services Requested: - 8 hours of on-site training and setup at DSCC - Unique Requirements: - Strict accuracy, distortion, power factor, and resolution specifications - Delivery required within 30 days of award - Brand name or equal is acceptable; no specific OEMs named - Place of Performance: - Defense Supply Center Columbus, 300 North James Road, Columbus, Ohio 43213 - DLA Product Test Center, Bldg 11-7 (TE Lab) - OEMs: - No specific OEMs or vendors mentioned; brand name or equal accepted

Description

The contractor shall provide all labor, materials, tools, transportation, supplies, supervision, etc. (except as noted), necessary to provide all components for a 18kVA 3Φ Power Supply Test System and 1kVA 3Φ Power Supply Test System to the Defense Supply Center Columbus (DSCC), Columbus, Ohio. The salient characteristics of the 3Φ Power Supply Test Systems are as listed below:

A. DC, 1Φ and 3Φ power system with support equipment with the following salient characteristics:

1.Shall be new, not refurbished. 2.Shall be supplied with Operating manual. 3.First system shall be capable of supplying: DC, 1Φ and 3Φ power from DC to 5kHz (sinusoidal, square wave, and arbitrary waveform) rated to 18kVA 4.Second system shall be capable of supplying: DC, 1Φ and 3Φ power from DC to 5kHz (sinusoidal, square wave, and arbitrary waveform) rated to 1kVA 5.Shall have accuracy of at least 0.15%. 6.Shall have no more than 0.3% distortion at 50/60Hz and no more than 1% distortion above these frequencies. 7.Shall have no less than 0.98 power factor. 8.Shall have resolution of no less than 0.1V. 9.Optional extended warranty and multi-year service contract must be offered. 10.Shall have: NIST Traceable Calibration Certificate and ISO 17025 accredited calibration certificate with data and uncertainties. 11.Shall include all the cables, sub-equipment and accessories for the system to reliably operate. 12.Shall be on a wheeled frame for easy movement. 13.Shall be able to fit through standard commercial double door (approximately 83”H x 70”W). 14.First system shall work as a single system to only require one 480V/3φ delta hard-wired disconnect for the entire system. Seconds system shall work as a single system to only require standard 120V/1φ 20A outlet.

B. Required Upgrades and Accessories - Brand Name or Equal: 1.GPIB, ethernet, USB Interfaces. 2.2 Windows 11 PCs with all necessary peripherals, hardware, ports, et cetera with software and permanent license to reliably control system. 3.8 hours of on-site training and setup.

C. Place of Performance

The instrument shall be delivered to: Defense Supply Center Columbus 300 North James Road, Bldg 17-3 Mark for: DLA Product Test Center, Bldg 11-7 (TE Lab) Columbus, Ohio 43213

Other Requirements: 1.Delivery: 30 days from date of the award. 2.Contractor shall give notification to Bradley Deslich (bradley.deslich@dla.mil/614-693-0182) when the instrument is ready to be delivered. 3.All shipping costs are to be included in the contracted price.