Opportunity

SAM #FA570226DM0002

Closed Loop Portable Wash Rack System for Al Udeid Air Base, Qatar

Buyer

United States Air Forces Central Command

Posted

May 04, 2026

Respond By

May 12, 2026

Identifier

FA570226DM0002

NAICS

333310, 333318, 238290, 423830, 488490

The U.S. Air Force and Defense Logistics Agency are seeking a closed loop portable wash rack system for Aerospace Ground Equipment at Al Udeid Air Base, Qatar. - Government Buyer: - U.S. Air Force, 379th Expeditionary Contracting Squadron (379 ECONS), U.S. Air Forces Central Command - Defense Logistics Agency (DLA), DLA Distribution San Joaquin - Products/Services Requested: - One closed loop portable wash rack system - Must include on/off ramps, pull-through (unenclosed) design, water inputs, oil-water separator (55-gallon capacity), high-pressure hot water wash equipment with integrated heating, 240/415V and 50 Hz power compatibility - Minimum 20 ft width, 40 ft length, load rating of at least 30,000 lbs, and portable construction - Oil-water separator must comply with AUAB 379th Environmental Management Plan discharge standards - Installation services at Al Udeid Air Base, Qatar - Includes site preparation on existing paved/asphalt surface, utility hookup (power and water within 50 ft), and system testing - No new concrete or grading required - Delivery services - Delivery to DLA Distribution San Joaquin, Tracy, CA, with subsequent shipment to Al Udeid Air Base, Qatar - Direct delivery to Al Udeid Air Base is preferred if locally sourced - Unique/Notable Requirements: - System must be portable and support heavy vehicles (30,000 lbs) - Oil-water separator must meet specific environmental standards - Installation must use existing paved surfaces; no government-furnished equipment or lodging provided - Award will be made to the lowest-priced, technically acceptable offeror - No specific OEMs or vendors are named in the solicitation

Description

Item Description – Portable Wash Rack Must include on and off ramp Must include pull through capabilities - unenclosed Must have inputs for water Must catch and separate oil and water i.e. have a oil-water sperator Needs to be 240/415V 50 hertz Must be at least 20 feet in width Must be rated to support 30,000 lbs Must be portable Must be delivered to   W62G2T

W1 AS DLA DIST SAN JOAQUIN

25600 S CHRISMAN ROAD, REC WHSE 57

TRACY, CA 95304-5000

Will require installation at Al Udeid Air Base to include site prep, utility hookup, and testing Quantity 1

View original listing