Opportunity
SAM #36C25026B0044
Construction Services for Imaging Tower Deficiencies at Cincinnati VA Medical Center
Buyer
VA Network Contracting Office 10
Posted
May 01, 2026
Respond By
May 15, 2026
Identifier
36C25026B0044
NAICS
236220, 238190, 238220, 238210, 238290
The Department of Veterans Affairs is seeking construction services to address imaging tower deficiencies at the Cincinnati VA Medical Center. - Government Buyer: - Department of Veterans Affairs, Network Contracting Office (NCO) 10, Cincinnati, OH - Scope of Work: - Complete construction services including labor, materials, equipment, and supervision - Full roof replacement above rooms A2013 and A2016 - Replacement of a lead-lined door in A2016 with a traditional double-door - Installation of a dedicated ductless split cooling system (up to 30k BTU/HR) in CT equipment room A2016A - Includes all required carpentry, power, and plumbing work - Set-Aside: - Reserved for service-disabled veteran-owned small businesses (SDVOSB) - Estimated Value: - Between $500,000 and $1,000,000 - OEMs and Vendors: - No specific OEMs, brands, or part numbers are mentioned - Place of Performance: - Cincinnati VA Medical Center, 3200 Vine Street, Cincinnati, Ohio - Notable Requirements: - Contractor must provide all necessary construction services and complete all work within 180 calendar days after Notice to Proceed
Description
Description of purpose work nature and volume:
The chosen contractor shall provide complete construction services including labor, materials, equipment, and supervision required to complete the Correct Imaging Tower Deficiencies project for the Cincinnati VAMC. This project requires a full roof replacement above A2013 & A2016, a lead-lined door replacement in A2016 (in favor of something like a traditional double-door where both sides open with operator) and improved cooling capacity within CT equipment room A2016A.
The [Correct Imaging Tower Deficiencies] project is intended to replace the full roof above A2013 & A2016, along with lead-lined door replacement in A2016 (in favor of something like a traditional double-door where both sides open with operator). Additionally, this project will add cooling capacity to CT control room A2016A through the placement of a dedicated ductless split system with capacity to cool at a rate of up to 30k BTU/HR. The installation of this should be all inclusive of all carpentry, power and plumbing work.
The above construction Statement Of Work (SOW) constitutes a basic outline of work and in no way outlines all of the details for the construction of this project. It is recommended that a detailed inspection of the premises, drawings and specification be initiated to determine the needs and conditions for the construction of this project.
Period of Performance:
All phases of work, including project closeout documentation, to be completed & provided within 180 calendar days after issuance of the Notice To Proceed (NTP).
The magnitude of construction project is estimated between $500,000 and $1,000,000
Location of the work:
All work to be performed, according to the drawings and specifications at the:
Cincinnati VA Medical Center
3200 Vine Street
Cincinnati, Ohio 45220-2637
Tentative dates for issuing invitations, opening bids, and completing contract performance;
The Invitation for Bids (IFB) should be posted on/about 05-29-2026 and the Bid Opening should be within 30-45 days thereafter.
Plans will be available for inspection without charge:
The specification and drawings will be available electronically with the IFB when released.
Date by which requests for the invitation for bids should be submitted:
There will be no physical copies provided.
Set-Aside:
This solicitation is set-aside for service-disabled veteran-owned small business (SDVOSB) concerns.
Amount to be charged for solicitation documents:
Not Applicable.
END OF SYNOPSIS