Opportunity
SAM #N4008526R9035
Comprehensive Painting and Coating Services for Buildings 1005 and 1005F at Camp Lejeune
Buyer
Naval Facilities Engineering Systems Command Mid-Atlantic
Posted
April 30, 2026
Respond By
June 02, 2026
Identifier
N4008526R9035
NAICS
236220, 238320, 562910, 238990
This opportunity seeks qualified contractors for comprehensive painting and coating services at Buildings 1005 and 1005F, Camp Lejeune, North Carolina. - Government Buyer: - Department of Defense, Department of the Navy, Naval Facilities Engineering Command (NAVFAC) Mid-Atlantic - Contracting office: NAVFACSYSCOM MID-ATLANTIC, Norfolk, VA - Resident Officer In Charge Of Construction (ROICC) Camp Lejeune - OEMs and Vendors: - Sherwin Williams (specified as a coating system manufacturer; "or approved equal" alternatives permitted) - MPI (Master Painters Institute) Approved Products List referenced for paint and coating certification - Products/Services Requested: - Painting and coating of exterior walls and doors for Building 1005 (22,000 SF walls, 15 doors) and Building 1005F (800 SF walls, 2 doors) - Application of specific paint/coating types per MPI standards: - Aluminum Paint (MPI 1) - High Heat Coating (MPI 22) - Interior Latex Paint (MPI 10) - Primer, Alkali Resistant (MPI 3) - Floor Enamel (MPI 27) - Elastomeric Coating (MPI 38) - Surface preparation, including cleaning, repair, and removal of non-adherent coatings - Lead-based paint encapsulation and hazardous materials abatement - Joint sealant replacement (ASTM C920 compliant) - Utility locating services (third-party, independent) - Asbestos hazard abatement and radiation safety compliance - Training for facilities management and maintenance personnel - Quality assurance testing and environmental controls - Unique/Notable Requirements: - Only pre-approved M&R MACC Contractors may submit proposals - Strict compliance with MPI product certification and environmental safety standards - Encapsulation of lead-based paint and abatement of asbestos hazards required - Training for building staff on new systems and safety procedures - Work must minimize interference with facility operations - Bonding and wage determination requirements apply - Place of Performance: - Camp Lejeune, North Carolina (Hadnot Point Industrial Area, Buildings 1005 and 1005F) - Contracting office in Norfolk, VA
Description
Only M&R MACC Contractors listed on the General Requirements cover page may submit a proposal for this ROICC Camp Lejeune area of responsibility project. See attached documents for scope of work and any applicable drawings.