Opportunity

PIEE #W911S226U3135

Procurement of Compact Liquid Chromatography Mass Spectrometer System for West Point

Buyer

MICC-Ft Drum

Posted

April 30, 2026

Respond By

May 15, 2026

Identifier

W911S226U3135

NAICS

334516

The U.S. Army is seeking to procure a compact liquid chromatography mass spectrometer system for delivery and installation at West Point, NY. - Government Buyer: - U.S. Army Materiel Command, S2P2 Contracting Officer - MICC-FT DRUM contracting office - OEMs and Vendors: - Shimadzu (brand name referenced, part number LCMS-2050) - Brand name or equal products permitted; all components must be manufactured and serviced by the same company - Products/Services Requested: - Compact liquid chromatographer with mass spectrometer - Part number: LCMS-2050 (Shimadzu) or equivalent - Quantity: 1 - Integrated instrument combining liquid chromatography and mass spectrometer - Unified software for both instruments - Dual ion source (electrospray ionization and atmospheric pressure chemical ionization) - Removable desolvation capillary - High energy conversion dynode detector - Autotuning and system check functions - Maximum nitrogen consumption: 15 L/min - Scan speed: 15,000 u/sec - Scan step resolution: 0.7u - Mass range: 2-2000 m/z - Delivery, installation, and 1-year warranty on parts and labor - Unique/Notable Requirements: - All system components must be from the same manufacturer and serviced by that company - System must support both qualitative and quantitative analysis in a single run - Brand name or equal offers accepted, but must meet all salient characteristics - Total Small Business Set-Aside - Compliance with Buy American and Balance of Payments Program - Place of Performance/Delivery: - Building 753 Cullum Road, West Point, NY 10996 (U.S. Military Academy) - Contracting office at MICC Fort Drum, NY

Description

Require an instrument that contains both liquid chromatography and mass spectrometer in paired/joined configuration. The preferred system for the liquid chromatograph and the mass spectrometer should have all items manufactured and serviced by the same company. The integrated software package should be able to operate and control both the mass spectrometer and liquid chromatograph instruments from a single unified operating platform. The system should be capable of performing both qualitative and quantitative analysis on a sample in a single run. Instrument must include all software to process quantification data and acquire samples, automatically restarts upon power failure and detect asymmetry in peak shape for quality assurance/quality control. The instrument must use a dual ion source that can provide both electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) to the same sample. Desolvation capillary must be removeable and replaced without breaking vacuum which allows for easier maintenance. The detector must use an off axis, high energy conversion dynode coupled with a discrete multistage active film electron multiplier, without phosphorconversion. Maximum nitrogen consumption needs to be 15 L/min or less for nebulization and drying purposes. Autotuning function must be included that optimizes both positive and negative ion modes, all scan speeds, mass axis calibration, sensitivity, and mass resolution automatically with a single tuning solution. Must include a system check to provide essential information on the status of the instrument and can be integrated into batches for smooth maintenance and troubleshooting. Scan speed needs to be 15,000 u/sec in 0.1u steps without reducing scan mass range. Scan step resolution should be 0.7u at all scan speeds. Mass range must be from 2-2000 m/z to enable analysis of a wide range of analytes including large peptides with multi-charge states. Must include delivery and installation to West Point NY, 10996 and include a 1-year warranty on parts and labor.According to DFARS 204.7304 Solicitation provision and contract clauses (c) This is a COTS item and 252.204-7012 would be exempted from this solicitation - this item does not need to be CMMC 2.0 compliant.

View original listing