Opportunity
SAM #FA441826Q0056
Sewer Lift Station Repair at Building 509, Joint Base Charleston
Buyer
628th Combat Sustainment Support Battalion
Posted
April 28, 2026
Respond By
May 11, 2026
Identifier
FA441826Q0056
NAICS
237110, 238290
The U.S. Air Force at Joint Base Charleston is seeking a small business contractor to repair the sewer lift station at Building 509. - Government Buyer: - Department of the Air Force, Air Mobility Command, 628th Contracting Squadron (628 CONS PK), Headquarters 628th Air Base Wing - Scope of Work: - Replace four standpipes and bases at the sewer lift station in Building 509 - Remove and reinstall four sewage pumps, guiderails, and guide rail brackets - Provide all labor, materials, and equipment required for the project - Perform OSHA Permitted Confined Space Entry for safe access - Install bypass pumps as needed during repairs - Test all components for full functionality after installation - Provide a one-year warranty on workmanship and materials - All excess and removed materials remain government property - Strict adherence to safety and environmental regulations is required - Products/Services Requested: - Standpipe and base replacement (4 units) - Sewage pump removal and installation (4 units) - Confined space entry and equipment replacement services - General labor, material, and equipment for lift station repair - Unique/Notable Requirements: - OSHA-compliant confined space entry - One-year warranty on all work and materials - Small business set-aside under NAICS 237110 - No specific OEMs, brands, or part numbers are specified in the solicitation - All work to be performed at Joint Base Charleston Air Base, South Carolina
Description
The project consists of providing all plant, labor, material parts, and equipment necessary to replace standpipes and bases on the sewer lift station at building 509 on Joint Base Charleston Air Base, South Carolina. See all attachments for full details. The project requirements include, but are not limited to the following major items of work:
Sewer Lift station Contractor Requirements: • Set-up to perform OSHA Permitted Confined Space Entry (CSE). • Plug manhole and install bypass pump while old equipment is being removed. • Pull pump #1 and perform CSE to remove #1 guiderails, standpipe and base. • Set new base, standpipe and reinstall existing guide rails using new guide rail brackets. • Repeat process for other three standpipes. • Once installed, all components will be tested for functionality to ensure normal operations.
This is a combined synopsis/solicitation for commercial products or commercial services prepared in accordance with FAR Part 12. This announcement constitutes the only solicitation. Offers are being requested and a separate written solicitation will not be issued.
Solicitation number FA441826Q0056 is issued as a request for quotation (RFQ) for the repair of the sewer lift station located at Building 509 on Joint Base Charleston Air Base.
This solicitation incorporates provisions and clauses by reference. The full text of provisions and clauses may be accessed electronically at www.acquisition.gov.
This acquisition is 100% set-aside for Small Business concerns. The associated NAICS code is 237110 with a size standard of $45,000,000.00.