Opportunity

SAM #52000QR260024561

USCGC Richard Etheridge Hull Maintenance and Anode Replacement Solicitation

Buyer

USCG Surface Forces Logistics Center Procurement Branch 1

Posted

April 28, 2026

Respond By

May 05, 2026

Identifier

52000QR260024561

NAICS

336611

The US Coast Guard Surface Forces Logistics Center (SFLC) is seeking hull maintenance services for the USCGC Richard Etheridge in Miami Beach, FL. - Government Buyer: - US Coast Guard Surface Forces Logistics Center (SFLC) Procurement Branch 1 - Products and OEMs: - Multiple OEM-specified anodes and fasteners required, with part numbers provided - Key products include: - Anode, B/T Gear Case (P/N: 1081226) - Anode, B/T Tunnel (P/N: CM2000Z) - Anode, Sea Chest Grate (P/N: GA-4) - Anode, Stern Tube (P/N: Z0020202H3 REV. 0) - Zinc Plate, Propeller (P/N: 950733) - Associated fasteners (nuts and screws with specified part numbers) - Services Requested: - Underwater hull inspection - Cleaning of the vessel's underwater body - Renewal of underwater zinc anodes - Documentation: written and audio-video inspection reports - Unique/Notable Requirements: - Certified divers and tender teams required - Compliance with commercial diving safety regulations (29 CFR 1910) - Pre-diving clearance and continuous two-way communication during diving - Detailed documentation of hull and running gear conditions - Set aside for small businesses under NAICS 336611 (Ship Building and Repairing) - Place of Performance: - USCGC Richard Etheridge, 100 McArthur Causeway, Miami Beach, FL 33139

Description

52000QR260024561 USCGC RICHARD ETHERIDGE HULL MAINTENANCE

This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR Subpart 12.6 as supplemented with additional information in this notice. This solicitation is issued as a Request for Quote Number 52000QR260024561 USCGC RICHARD ETHERIDGE HULL MAINTENANCE.

 This procurement will be processed in accordance with FAR Part 12.

The North American Industry Classification System (NAICS) is 336611 - Ship Building and Repairing. This is a total small business set aside; all responsible small business sources may submit proposals that will be considered. This synopsis/solicitation is issued pursuant to FAR 13.106-1(b), and the resultant purchase order will be awarded on a firm-fixed price basis using simplified acquisition procedures in accordance with FAR 13.

THE UNITED STATES COAST GUARD SURFACE FORCE LOGISTICS CENTER REQUESTS THE CONTRACTORS TO PROVIDE PRICING FOR THE FOLLOWING REQUIREMENT:

The contractor shall provide services for 52000QR260024561 USCGC RICHARD ETHERIDGE HULL MAINTENANCE.

Hull Plating, U/W Body, Diver’s Inspect, Clean and Renew U/W Zinc Anodes Perform

SCOPE

Intent. This work item describes the requirements for the Contractor to conduct a hull inspection, cleaning of the vessel’s U/W body, and renewal of U/W zinc anodes. Affected surfaces or components include, but are not limited to the following:

U/W hull plating. U/W body coating system. Transducer(s)/sonar dome. Drive Systems Appendages Cathodic Protection

Government-furnished property.

MTI

ITEM DESCRIPTION

NSN/PN

QTY

N

Anode, B/T Gear Case

P/N: 1081226, NIIN: 015485655

1

N

Anode, B/T Tunnel

P/N: CM2000Z

NIIN: 200126334

12

N

Anode, Sea Chest Grate

P/N: GA-4, NIIN: 016476179

4

N

Anode, Stern Tube

P/N: Z0020202H3 REV. 0, NIIN: 016445483

16

N

Nut, Self-Locking,

P/N: 90715A145, NIIN: 015085774

32

N

Screw, Prop Zinc Plate

P/N: 950756, NIIN: 016340210

8

N

Screw, Sea Chest Grate Anode

P/N: 93190A634, NIIN: 016197182

2

N

Screw, Stern Tube Covers

P/N: 90585A626, NIIN: 016161107

42

N

Zinc Plate, Propeller

P/N: 950733, NIIN: 016278941

2

REFERENCE

OTHER REFERENCES

Code of Federal Regulations (CFR) Title 29, Part 1910, Subpart T, 2007, Commercial Diving Operations

REQUIREMENTS

General.

CIR.

None.

Tech Rep.

Not Applicable.

The Contractor must provide the Coast Guard Inspector 24 hours advance notice of when the diver inspection will occur. Before diving procedures are commenced, meet with the COR and the Coast Guard Inspector, to discuss diving safety requirements and the securing of cutter machinery, as applicable.

NOTE

At Contractor’s request, Ship’s force will secure and tag out the cathodic protection system, main engines, steering gear, generator set, A/C unit, fire pumps, and all other machinery which may cause a hazard while a diver is in the water.

Pre-diving clearance. The Contractor must ensure that the diving team must obtain clearance from the Officer-of-the-Deck before beginning diving operations. Ensure the Coast Guard Inspector has capability for maintaining continuous two-way communication with diving personnel at all times, during the performance of this work item.

Support and safety procedures. The Contractor shall follow all safety protocols, including the use of proper personal protective equipment, and adhere to all safety regulations during diving and hull inspection activities.

Inspection procedures. The Contractor shall conduct a thorough inspection of the hull, including visual assessment, measurement, and documentation of any damages or corrosion.

Reporting. The Contractor shall prepare detailed reports of the inspection findings, including photographs, measurements, and recommendations for repairs or maintenance.

Post-inspection activities. The Contractor shall ensure all equipment is properly stored, and the work site is left in a safe condition after completion of the inspection.

END OF SCOPE

View original listing