Opportunity

SAM #F3N0616023A006

Installation of Commercial-Grade Electrical Outlets in Maintenance Shelters at Ramstein Air Base

Buyer

700th Consolidated Group

Posted

April 27, 2026

Respond By

May 09, 2026

Identifier

F3N0616023A006

NAICS

238210

The U.S. Air Force at Ramstein Air Base, Germany, is seeking installation of commercial-grade electrical outlets in two Large Area Maintenance Shelters (LAMS) to support cargo and administrative operations. - Government Buyer: - Department of the Air Force, 86th Airlift Wing (USAFE), 700 CONS PK - OEMs and Vendors Mentioned: - Steidle (outer distribution panels) - Spelsberg (inner distribution panels) - Hager (fuses) - Weidmuller (DIN rail terminal blocks) - Merten (Aquastar moisture-proof outlets) - Products/Services Requested: - Installation of twelve (12) 230V, 50Hz moisture-proof electrical outlets (six per tent) - Outer distribution panel (Steidle or equivalent) - Two inner distribution panels (Spelsberg or equivalent) - Twelve B16A fuses and two 63A main fuses (Hager or equivalent) - Thirty-six DIN rail terminal blocks (Weidmuller or equivalent) - Twelve Merten Aquastar moisture-proof outlets (or equivalent) - All necessary wiring, conduit, mounting hardware, and labor - Unique/Notable Requirements: - All installations must comply with U.S. National Electrical Code (NEC/NFPA 70) and German VDE standards - Outlets must be moisture-proof/weather resistant and suitable for outdoor or semi-covered environments - Power must reliably support laptops, radios, fans, and administrative equipment - Work to be performed during normal business hours, excluding U.S. federal and German holidays - No specific part numbers provided; "or equivalent" products are acceptable - Place of Performance: - Large Area Maintenance Shelters adjacent to Building 3452, Ramstein Air Base, Germany

Description

SEE ATTACHED PERFORMANCE WORK STATEMENT AND SALIENT CHARACTERISTICS

The proposed contract action is anticipated to be full and open compitition it requires installation of electrical outlets inside the two Large Area Maintenance Shelter (LAMS) to support Cargo. Deployment Function (CDF) operations. Each tent requires six 230-volt outlets, for a total of twelve outlets. The requirements include all parts and labor necessary to complete the electrical outlets installation.

All electrical installations must comply with the National Electrical Code (NEC/NFPA 70) for U.S. requirements and Verband der Elektrotechnik (VDE) standards for German Electrical Installations, and all applicable civil engineering regulations. 

IAW RFO 5.101(c)(2): Set asides are not applicable in Germany.

IAW RFO 5.101(c)(4):

(iii) Is not applicable to this requirement 

(vi) All responsible sources are invited to submit a response to show interest which will be considered by the agency. Please note that this not a Request for Quotation but rather a pre-solicitation notice, and no quotes will be accepted in response at this time.

(viii) Installation Specifications for Electrical Outlets

Quantity: 12 total outlets ( 6 per tent across two tents) Power rating: 230V, 50Hz (standard European system) Materials: Commercial grade receptacle, wiring, conduit, distribution board components, fasteners, and mounting hardware. Features: supports laptops, radios, fans, and administrative equipment. Qualification requirement: (NEC/NFPA 70) or (VDE) as mentioned above.