Opportunity
Merx #0000320300
Fire Alarm System Replacement and Building Upgrades at René Tremblay Building, Matane, Quebec
Posted
April 24, 2026
Respond By
May 13, 2026
Identifier
0000320300
NAICS
238210, 238190, 238350
This opportunity involves a comprehensive fire safety upgrade at the René Tremblay building in Matane, Quebec, managed by BGIS - PWGSC RP1 under SPAC oversight. - Government Buyer: - BGIS - PWGSC RP1 (Public Services and Procurement Canada Real Property 1), overseen by SPAC (Services publics et Approvisionnement Canada) - Scope of Work: - Replacement of the entire fire alarm system - Replacement of the fire alarm annunciator in the basement - Addition of a ULC-certified fire alarm communicator - Correction of building deficiencies - Replacement of existing folding doors and frames in janitorial rooms R105, R204, and R301 with ULC-approved 45-minute fire-rated swinging doors - Architectural and electromechanical interventions as required - Selective demolition of suspended ceilings - Surface repairs and finishing - Installation and finishing of new fire doors and frames - Protection of existing surfaces and equipment during construction - Products/Services Requested: - No specific OEMs, vendors, or part numbers are mentioned - All fire doors and alarm components must meet ULC (Underwriters Laboratories of Canada) certification requirements - Unique Requirements: - All new doors must be ULC-approved and provide a 45-minute fire rating - Work includes both architectural and electromechanical elements, as well as careful protection of existing infrastructure during the project - Place of Performance: - René Tremblay building, 150 Boul. Dion, Matane, Quebec, G4W 4T6
Description
This solicitation is for the replacement of the fire alarm system, including the replacement of the fire alarm annunciator in the basement, addition of a ULC fire alarm communicator, and correction of certain deficiencies at the René Tremblay building located at 150 Boul. Dion, Matane, Quebec. The work also includes replacing existing folding doors and frames in janitorial rooms R105, R204, and R301 with ULC approved 45-minute fire-rated swinging doors, along with associated architectural and electromechanical work related to the fire alarm equipment replacement. The scope involves selective demolition of suspended ceilings, surface repairs and finishing, installation and finishing of new fire doors and frames, and protection of existing surfaces and equipment throughout the work duration.