Opportunity

SAM #W81K0426QA043

Request for Information for Medical Grade Curtains for Womack Army Medical Center

Buyer

U.S. Army Health Care Acquisition Activity

Posted

April 15, 2026

Respond By

April 24, 2026

Identifier

W81K0426QA043

NAICS

314120

This Request for Information seeks vendor input for supplying medical grade curtains to Womack Army Medical Center at Fort Bragg, North Carolina. - Government Buyer: - Department of Defense, Department of the Army, US Army Medical Command, US Army Health Contracting Activity (W40M USA HCA) - Products/Services Requested: - Medical grade railroaded cubicle curtains for patient rooms - No specific OEMs or part numbers identified - Vendors are to supply curtains only; installation will be performed by Womack personnel - Technical and Clinical Requirements: - Minimum length and width specified - Standard track heading, gold color - Flat seams with double needle lock stitch, double-stitched hems - NFPA 701 fire safety compliance - Antimicrobial properties - Fabric must withstand laundering at up to 160 degrees - Mesh portion: 100% nylon, gold color, specific fabrication and aperture size - Privacy features: overlapping panels and vertical snaps - Vendor Requirements: - Must be registered in SAM with NAICS code 314120 (Curtain and Linen Mills) - Place of Performance: - Fort Bragg, North Carolina - Additional Notes: - No telephonic inquiries will be answered - Formal solicitation will be posted on SAM.gov

Description

This is a Request for Information (RFI) – Sought Notice Only. This notice is issued solely for information and planning purposes only.  

1. The US Government will not pay for any information or administrative costs incurred in response to this notice. Submittals will not be returned to the responder; not responding to this notice does not preclude participation in any further RFQ; IFB or RFP if issued.  

2. The associated North American Industry Classification System (NAICS) is 314120. The business size standard is 750 Employees. All contractors doing business with the Department of Defense shall be registered and approved through the System for Award Management (SAM). This is the Official U.S. Government system that consolidates the capabilities of CCR/FedReg, and EPLS. There is no fee to register for this site. Entities may register at no cost directly from this page. The proposed performance start date will be on or about 1 April 2026. The Solicitation number is W81K0426QA043.  

3. Note – Prior to award your company shall reflect the NAICS Code 314120 identified on your SAM. If your company is interested in competing on this project, and have services, please submit the following documentation no later than  24 April 2026, 10:00 AM EST, to Cynthia A. Richardson-Rhone and Jason Holck at cynthia.a.richardson-rhone.civ@health.mil.  All questions need to be submitted NLT 22 April 2026 by 10:00 AM EST.

Your email response shall provide the following:

Can you provide the following:

Railroaded Cubicle Curtains for Womack Army Medical Center.  The curtains will go inside of the patient’s room replacing the worn curtains or installing them where needed.  The vendor will only supply the curtains.  They will be installed by Womack personnel. 

Salient Characteristics:

Minimum Clinical Performance Requirements

-Overall, Curtain length with mesh: To be determined by Contractor based on criteria of 12” above finished floor, (AFF), allow 56” for panel height and 20” (+/-) at mesh for a total of 76’’ length, with the width of 136’’.

-Curtain Fullness: Length of track plus 12% additional fullness

-Curtain Heading: Standard track heading; Color: Gold

-Curtain Seams: Flat, ½” gauge double needle lock stitch, 100% mercerized cotton thread

-Curtain Hems: Double turned, twin needle stitched, 100% mercerized cotton thread

-Curtain Hem Size: 1” Double-stitched bottom and side hem

-Fabric Testing: Passes National Fire Prevention Association (NFPA) 701

-Mesh: 100% Nylon; Color: Gold

-Mesh Fabrication: continuous; “Z” folded to the body of the curtain

-Mesh opening size: ½” aperture

-Mesh portion to consist of (+/-) 30” of large-scale heavy nylon mesh

-Top 1 ¼” woven selvage banding shall be folded before final sewing

-Double row stitching 7/8” inch apart shall be used on all banding

-Provide beige/aluminum snaps, Dia.: .5”; anodized aluminum or painted white snaps

-Snaps located every 4” o. C

-Privacy curtain fabric panels shall be installed to provide continuous track coverage by overlapping each       panel 4 inches and vertical snaps provided for privacy between panels on 8” o. C Provide beige/aluminum snaps, Dia.: .5”; anodized aluminum or painted white snaps.

-Finished privacy curtain panel size approx. 136” w X 74”h from bottom of mesh header to finished

length of panel.

Source Considerations

Fire Safety Compliance- Meet NFPA 701 standard

Biomedical Tech Considerations

Infection Control: Antimicrobial Curtains Fabric Durability: Able to be laundered at temperatures of 160 degrees max

Please ensure to address the below:

Name of Company Point of contact Phone number Email address Identify Your Small Business Socio-Economic Group DUNS number and CAGE Code

4. This requirement No telephonic inquiries will be responded to. A solicitation will be posted within 2-3 weeks www.Sam.gov.

               