Opportunity

Brazos Valley Ionwave #014-06-26

Procurement of Spun Prestressed Concrete Poles for 138kV Transmission Line

Posted

March 25, 2026

Respond By

April 22, 2026

Identifier

014-06-26

NAICS

332996

Bryan Texas Utilities (BTU), a municipal electric utility under the City of Bryan, Texas, is seeking bids for the supply of spun prestressed concrete poles for the Rayburn-East Reroute 138kV Transmission Line Project. - Government Buyer: - Bryan Texas Utilities (BTU), Purchasing Department, City of Bryan, Texas - Products Requested: - Fourteen (14) spun prestressed concrete poles of various types and dimensions for 138kV single circuit transmission lines - Types and part numbers include RER-S-TAN 100/15, RER-S-TAN 105/15, RER-S-TAN 110/15, RER-S-RA10 105/15, RER-S-RA10 115/15, RER-S-RA10 120/20, RER-S-RA20 115/20, RERE-S-TAN 100/15, RERE-S-TAN 105/15, RERE-S-TAN 110/15, RERE-S-TAN 115/15, RERE-S-TAN 130/20, RERE-S-RA15 105/15, RERE-S-RA15 115/20 - Poles range from 100 ft to 130 ft above ground, with embed depths of 15 ft or 20 ft, and overall lengths up to 150 ft - Includes step bolt inserts, ground clips, and mounting hardware per Entergy specification TC0609 Rev. 05 - Step bolts (3/4" or 5/8" diameter, A394 grade) and associated inserts per Entergy specification TDS069A1 - Technical and Quality Requirements: - Poles must comply with Entergy's technical specifications, including design, material, fabrication, testing, and inspection standards - Compliance with ASTM and PCI industry standards is mandatory - Detailed quality assurance and insurance requirements apply - Delivery and Performance: - Delivery of all poles to Bryan Texas Utilities Electrical Warehouse at 611 Union Street, Bryan, TX - Delivery must be completed by the specified deadline, with coordination required between BTU and the selected vendor - OEMs and Vendors: - No specific OEMs are named; any qualified concrete pole fabricator meeting the technical and quality requirements may bid - Notable Requirements: - Strict adherence to Entergy's design, fabrication, and quality assurance standards - All hardware and accessories must be included as specified - Delivery schedules are firm and must be coordinated with BTU

Description

This solicitation is a request for bids for the purchase of spun prestressed concrete poles for the Rayburn to East Re-Route 138kV transmission line. The procurement includes design, material, fabrication, testing, inspection, and delivery of poles for use on the Entergy system transmission lines. Bids can be submitted electronically or as sealed hard copies by April 22, 2026. The poles must meet detailed technical specifications and standards as outlined in the provided documents, including compliance with Entergy's design and quality requirements.

View original listing