Opportunity

City of Moline Ionwave #CHS-H-10-50 Addendum 1

City of Moline Solicitation for Smoke/CO Detector System and Boiler Renovation at 1032 13th Avenue

Posted

March 09, 2026

Respond By

March 24, 2026

Identifier

CHS-H-10-50 Addendum 1

NAICS

238290

This opportunity involves renovation work for the City of Moline's Community Housing Services Program at 1032 13th Avenue, Moline, IL. - Government Buyer: - City of Moline, Community Housing Services Program - Project managed by Christopher Day - Products and Services Requested: - Installation of an interconnected smoke and carbon monoxide detector system - Must comply with NFPA 72: National Fire Alarm & Signaling Code and local codes - Includes new detector in basement, placement on all home levels, and testing for interconnectivity - Boiler system renovation (gas custom) - Remove and replace deteriorated water/steam lines in basement (approx. 45 feet) - Repair or replace non-functioning radiators on first and second floors - Insulate piping, clean dust/debris, test and service all boiler components (thermostat, valves, seals, safety controls, electrical, flue, CO levels) - Provide servicing schedule and homeowner education on boiler operation and maintenance - General construction requirements - All materials must be new and installed per manufacturer specifications - Compliance with City of Moline, Rock Island County, and Illinois state codes - One-year warranty on workmanship and materials - Debris removal and final cleaning - Provision of warranties and manuals for all work performed - OEMs and Vendors: - No specific OEMs or brands are mentioned; open to qualified vendors able to meet technical and compliance requirements - Unique or Notable Requirements: - Pre-bid site visit required - Electronic bid submission - Homeowner education component - Strict adherence to NFPA 72 and local building codes - All work must be warrantied for one year

Description

The City of Moline invites bids for renovation work at 1032 13th Avenue under the Community Housing Services Program. The project includes installing an interconnected smoke/CO detector system in compliance with NFPA 72 and local codes, as well as removing and replacing deteriorated water and steam lines in the basement servicing radiators on the first and second floors. The work also involves ensuring proper boiler operation, repairing or replacing non-functioning radiators, and providing homeowner education on boiler maintenance. Bids must be submitted electronically by March 24, 2026, with a public bid opening held online.

View original listing

Get AI summaries, saved searches, and real-time alerts for new opportunities. Sign up free · Sign in