Opportunity
SAM #140P8226B0005
Replacement of 17.5-Ton Carrier Rooftop Cooling Unit at War in the Pacific National Historical Park, Guam
National Park Service
March 23, 2026
March 31, 2026
140P8226B0005
238220
This opportunity involves the National Park Service seeking construction services for the replacement of a 17.5-ton Carrier rooftop Package Cooling Unit (PCU) at the T. Stell Newman Visitor Center, War in the Pacific National Historical Park, Guam. - Government Buyer: - National Park Service (NPS), Pacific West Region, PWR HONO MABO office - OEM Highlight: - Carrier is the specified Original Equipment Manufacturer for the new PCU - Products and Quantities: - 1 x Carrier 17.5-ton rooftop Package Cooling Unit (208V, 3-Phase, 60 HZ) - Associated appurtenances: exterior supply and return air ducts, condensate drains, outdoor air hood with manual damper, electrical power cable, panel, controls, and thermostat controller - Services Requested: - Removal and disposal of existing PCU #3 and appurtenances - Power washing and preparation of the existing concrete pad - Installation, connection, calibration, troubleshooting, and commissioning of the new Carrier PCU and appurtenances - Unique Requirements: - Rooftop installation requiring crane operation - Protection of grounds and compliance with NPS regulations, safety, environmental, and quality control requirements - Installation and commissioning must follow Carrier manufacturer instructions - Place of Performance: - T. Stell Newman Visitor Center, War in the Pacific National Historical Park, Guam - NAICS Code: - 238220 (Plumbing, Heating, and Air Conditioning Contractors) - Opportunity Type: - Sources Sought/Market Research (not a solicitation for bids)
Description
Sources Sought to REPLACE 17.5-TON PACKAGE COOLING UNIT (PCU) & APPURTENANCES AT THE VISITOR CENTER at WAR IN THE PACIFIC NATIONAL HISTORICAL PARK (WAPA) GUAMThis is a Sources Sought announcement to be used for preliminary market research purposes only. No bids are being requested or accepted from this announcement. THIS IS NOT A SOLICICTATION FOR BIDS AND NO CONTRACT SHALL BE AWARDED FROM THIS SYNOPSIS. The type of solicitation to issue will depend upon the responses to this synopsis. No reimbursement will be made by the Government for any costs associated with providing information in response to this synopsis of a follow up information. The purpose of this synopsis is to gain knowledge of interest, capabilities and qualifications of various members of 8(a), HUBZone, Service-Disabled Veteran-Owned Small business (SDVOSB), Women Owned Small Business (WOSB), Economically Disadvantaged Women Owned Small business (EDWOSB), and Indian Small Business Economic Enterprises (ISBEE) to compete and perform a Firm Fixed Price contract.The National Park Service, ConOps West, has a requirement to Replace 17.5 Ton Packaging Unit (PCU) and Appurtenances at the Visitor Center at War in the Pacific National historic Park (WAPA) Guam. Work will consist of the following:• Replace the existing PCU #3 and appurtenances on the roof of the T. Stell Newman Visitor Center at War in the Pacific National Historical Park• Remove and properly dispose of the existing PCU #3 and appurtenances• Power wash the existing concrete pad (8’ wide x 11’-4” long x 5.5” high) in preparation for the new PCU. Properly contain and dispose of debris and water from power washing• Install a new 17.5-Ton Carrier Model PCU meant for rooftop applications in inclement weather on the existing 8’ x 11’-4” concrete pad on the roof. The new PCU shall be 208V, 3-Phase, 60 HZ. The PCU must fit on the existing concrete pad, and the return / supply ducts must be positioned in the rear of the unit facing the wall.• The new PCU shall be placed with a crane with adequate load capacity and operating permits, careful not to damage the existing building, grounds, grass, or surrounding area. Protect ground surfaces with plywood or other surface protections.• The new PCU shall be anchored to the existing concrete pad per manufacturer’spublished installation instructions.• The Contractor shall replace all PCU appurtenances to include the exterior supply and return air ducts, condensate drains, outdoor air hood with manual damper package, and electrical power cable, panel, and controls• The Contractor shall also replace the thermostat controller to work with the new PCU.• The new PCU and appurtenances shall be installed, connected, calibrated, and operable per the manufacturer’s published recommendations. Complete troubleshooting and commissioning as needed.Project Location: WAR IN THE PACIFIC NATIONAL HISTORICAL PARK (WAPA) GUAMThe acquisition is subject to the North American industry Classification System (NAICS) code of 238220, Plumbing, Heating, and Air Conditioning Contractors. The Small Business Size Standard for this NAICS code is $19M. Vendors responding to this sources sought notice should include the following information:1. Company name, address, UEI number, point of contact, telephone number and email address.2. Examples of relevant experience performing similar projects to demonstrate capability (at a minimum, include a brief description of project, project dates, and customer name/agency)3. Provide the company’s business size (small or other than small) and all applicable socio-economic category information (Small, 8(a), HubZone, SDVOSB, WOSB, EDWOSB, ISBEE).Vendors should provide information regarding this announcement by emailing Michael_davidson@ios.doi.gov no later than the due date posted on SAM. Email subject line must include “Sources Sought Notice 140P8226B0005