# North Carolina eVP #148-MAINT-058

Asheville High School Varsity Gym Curtain Wall and Door Replacement

**Posted:** November 24, 2026
**Respond By:** December 11, 2026
**Identifier:** 148-MAINT-058
**NAICS:** 332321, 238150

Asheville City Schools is seeking a contractor to replace the curtain wall and door assemblies at Asheville High School’s varsity gym.
- Buyer: Asheville City Schools, State of North Carolina; Asheville, Buncombe County.
- Scope: Furnish and install one aluminum curtain wall system, approximately 12 inches deep, with a deep face cap and black Kynar finish, plus four pairs of wide-stile aluminum doors, each pair approximately six feet wide.
- Door hardware: Four sets each of continuous hinges, **Von Duprin** rim panic exit devices, removable mullions, **LCN 4040 XP** surface-mounted closers, and **BEST** cylinder housings for owner-provided lock cores.
- OEMs/brands: **Von Duprin**, **LCN**, and **BEST** are named for hardware; Kynar is specified as the finish. No curtain-wall or door-system manufacturer is specified, and no part numbers are provided except LCN 4040 XP.
- Installation requirements: Verify dimensions and site conditions before fabrication; furnish required framing, anchors, seals, fasteners, sealants, and accessories; coordinate work with the school; and adjust and test the installed doors and hardware.
- Exclusions and warranty: Demolition and removal of existing frames, lock cores, and keying are excluded. Provide applicable manufacturer warranties and at least a one-year workmanship warranty.

### Description

Asheville City Schools is seeking proposals to furnish and install a new aluminum curtain wall system and associated door assemblies at the Asheville High School Varsity Gym Building. The work includes a curtain wall system, four pairs of wide-stile aluminum doors, required framing and accessories, and specified commercial-grade door hardware. Contractors must field-verify dimensions, schedule a mandatory site visit, and include pricing, qualifications, project examples, estimated timeline, and applicable warranties in their proposals. Existing-frame demolition and removal, BEST lock cores, and lock keying are excluded from the contractor’s scope.

[View original listing](https://evp.nc.gov/solicitations//details/?id=46468143-1be8-f111-84e9-001dd803db57)