# SAM #N3904027Q5950

Annual calibration of a PAMAS SBSS particle analyzer

**Buyer:** Portsmouth Naval Shipyard
**Posted:** November 20, 2026
**Respond By:** November 25, 2026
**Identifier:** N3904027Q5950
**NAICS:** 334516

The Department of the Navy is seeking recurring calibration of a PAMAS particle-analyzing system at Naval Base Point Loma.
- **Government buyer:** Department of the Navy, Naval Sea Systems Command (NAVSEA), Portsmouth Naval Shipyard, Contracting Code 410; work location is Naval Base Point Loma, Building 633, Floor 2, San Diego, California. Requiring office: C134.
- **OEM:** **PAMAS Partikelmess- und Analysesysteme** (PAMAS), manufacturer of the SBSS system.
- **Equipment:** One PAMAS SBSS Particle Analyzing System, serial number 320-2346.
- **Requested service:** Five calibrations—one base-period calibration and four option-period calibrations. Pricing is to include labor, materials, travel, freight, and data deliverables.
- **Technical requirements:** Calibration must comply with ISO 11171 and ISO 4402 and be traceable to NIST SRM 2806d. Required particle-size ranges are 4.0–70 µm(c) under ISO 11171 and 1.0–100.0 µm under ISO 4402. Work includes syringe function check/replacement if needed, molecular sieve replacement, and mechanical and vacuum checks.
- **Provider qualifications and deliverables:** Calibration must be performed by a currently certified/accredited authority or the OEM. Provide a calibration certificate/report and, if unscheduled repairs are identified, a condition-found report. Additional training may be required; repairs beyond scheduled calibration require Contracting Officer authorization.
- **Other requirement:** Contractors and subcontractors must protect controlled unclassified and other sensitive information under Portsmouth Naval Shipyard OPSEC requirements, including applicable device, photography, public-disclosure, and incident-reporting controls.
- **Period:** One base year plus four option years, for up to five years of annual calibration service.

### Description

<p>Calibrate PAMAS SBSS s/n 320-2346 per ISO 11171 Hydraulic fluid power Calibration of automatic<br />
particle counters for liquids and is traceable to SRM 2806d AND per ISO 4402 Hydraulic fluid power<br />
Calibration of automatic-count instruments for particles suspended in liquids.</p>

<p>1.2. Location of Work: Naval Base Point Loma, 140 Sylvester Rd., Bldg. 633, Fl 2,</p>

[View original listing](https://sam.gov/opp/7854cc2258d4429d88f50a77f602eac5/view)