# SAM #097819097820

Navy seeks capability statements for QuidelOrtho VITROS XT 7600 laboratory supplies

**Buyer:** Department of the Navy
**Posted:** November 20, 2026
**Respond By:** November 30, 2026
**Identifier:** 097819097820
**NAICS:** 325413

The Department of the Navy is seeking sources for a contemplated sole-source purchase of laboratory supplies for USNS Comfort’s QuidelOrtho VITROS XT 7600 analyzer.
- **Opportunity:** Intent to sole source; this is not a competitive request for proposals. The Navy may consider capability statements to determine whether competition is appropriate.
- **Buyer and user:** Department of the Navy; USNS Comfort (T-AH 20), homeported at Naval Station Norfolk, Virginia.
- **OEM and system:** QuidelOrtho VITROS XT 7600 Integrated System. The requested supplies must be OEM products compatible with the analyzer.
- **Items:** Sample tips, cuvettes, cups, trays, waste liners, printer paper, optical cleaner, system fluids, reagents, diagnostic tests, calibrators, lot-data materials, and quality controls. The test menu spans clinical chemistry, renal, liver, lipid, specialty protein, drug monitoring, cardiac, thyroid, infectious disease, reproductive endocrinology, and oncology testing.
- **Quantities and part numbers:** Not specified in the notice narrative. The Bill of Materials (BOM) will establish the final items, part numbers, units of issue, and quantities. Analyzer onboard capacities described for some supplies are not purchase quantities.
- **Delivery and compliance:** One shipment is contemplated, with timing coordinated with the Government. Split shipments require prior approval; substitutions or items outside the BOM require written Contracting Officer authorization. Products must be suitable upon delivery and handled and delivered in accordance with OEM requirements.
- **Response dates:** Capability statements are due November 30, 2026. The detailed BOM is due on or before December 14, 2026.
- **Capability statement contents:** Management and technical information, pricing, business size, and CAGE code.

### Description

<p>Pre-Solicitation Notice</p>

<p>Notice of Intent to Sole Source</p>

<p><strong>Background:</strong></p>

<p>The United States Naval Ship (USNS) Comfort (T-AH 20) is a 1,000-bed hospital ship that provides rapid response capability for Combat Casualty Care, Humanitarian Assistance, and Disaster Relief operations worldwide. USNS Comfort provides the National Command Authority with unparalleled healthcare capability in support of America&rsquo;s strategic interests. To support its clinical laboratory mission, USNS Comfort (T-AH 20), home port Naval Station Norfolk, VA, operates the&nbsp;<strong>QuidelOrtho VITROS&reg; XT 7600 Integrated System</strong>, a high-throughput, waterless clinical laboratory analyzer that combines digital chemistry imaging and immunodiagnostic testing.</p>

<p><strong>Need:</strong></p>

<p>The Government requires a one shipment for quantities of supplies necessary to support projected laboratory testing requirements.</p>

<p>The Contractor shall furnish 100 percent of the Government-approved quantities shown below for each this purchase, except where shipment of the full quantity is not feasible due to OEM shelf-life, storage, packaging, or transportation limitations. In such cases, the Contractor shall notify the Government and obtain approval prior to making any split shipment.</p>

<p>The Contractor shall:</p>

<ol>
	<li>Furnish all supplies identified in this SOW and the applicable Bill of Materials.</li>
	<li>Provide only OEM supplies suitable for their intended use upon delivery.</li>
	<li>Ensure all delivered items are compatible with the QuidelOrtho VITROS XT 7600 Integrated Systems.</li>
	<li>Package, handle, transport, and deliver all items in accordance with applicable OEM requirements.</li>
	<li>Coordinate shipment timing with the designated Government representative prior to shipment.</li>
	<li>Notify the Government promptly of any actual or anticipated supply constraint, discontinuance, backorder, or shelf-life issue affecting performance.</li>
	<li>Not provide substitute, additional, or non-scope items without prior written authorization from the Contracting Officer.</li>
</ol>

<p><strong>Out-of-Scope Requirements</strong></p>

<p>Products, supplies, or services not specifically identified in this SOW or the applicable Bill of Materials are outside the scope of this requirement. The Contractor shall not furnish substitute, additional, or non-scope items without prior written authorization from the Contracting Officer. A verbal discussion, inquiry, recommendation, or notice shall not constitute authorization.</p>

<p></p>

<p><strong>Technical Consumable Classifications &amp; Bill of Materials</strong></p>

<p><strong>General</strong></p>

<p>The supply requirement shall consist of product categories specific to the VITROS XT 7600 systems. All materials supplied under this requirement shall meet applicable OEM specifications and be fully compatible with the supported analyzers. The detailed Bill of Materials shall identify the required items, part numbers, units of issue, and quantities for this shipment on or before 14 December 2026.</p>

<p><strong>Mechanical &amp; Fluid Consumables (Disposable Plastics &amp; System Packs)</strong>&nbsp;</p>

<p>Item Code / Description</p>

<p>Form Factor / Packaging</p>

<p>Primary Function / Onboard Specification</p>

<p>Vitros VersaTips</p>

<p>Mutli-racks packs (Bulk case)</p>

<p>Single-use sample aspiration/dispense tips: 2,000 onboard capacities</p>

<p>Vitros MircoTips</p>

<p>Strip packs / cartridges</p>

<p>Specialized pipette tips for liquid chemistry dispensing; onboard capacity: 384 tips</p>

<p>Vitros Cuvettes</p>

<p>Stack packs</p>

<p>Reaction vessels for MicroTip liquid chemistries; onboard capacity: 348 cuvettes</p>

<p>Microsample Cups</p>

<p>(0.5 mL &amp; 2.0 mL)</p>

<p>Bulk cases</p>

<p>Pediatric, low-volume, and standard STAT secondary aliquot cups</p>

<p>Universal Sample Trays &amp; Inserts</p>

<p>Trays accommodating 5/7/10 ML</p>

<p>Sample management carriers for routine loading rings and STAT rack position</p>

<p>Waste Disposal Bags / Solid Waste Liners</p>

<p>Custom-fit biohazard heavy-gauge liner</p>

<p>Solid waste collection bins for spent dry slides, used tips, and reaction cuvettes</p>

<p>Printer Paper &amp; Optical Cleaner</p>

<p>Direct OEM accessories</p>

<p>Maintenance and system audit documentation consumables</p>

<p></p>

<p></p>

<p><strong>&nbsp;System Operational Fluids &amp; Reagent Packs</strong>&nbsp;</p>

<p>Item Code / Product Name</p>

<p>Nominal Packaging</p>

<p>Functional Role &amp; Onboard Storage Requirements</p>

<p>VITROS Signal reagents</p>

<p>Multi-Pack kit</p>

<p>(Reagent A &amp; B)</p>

<p>Chemiluminescent substrate for MircoWell assays; onboard capacity: 3 Packs; replenishment on-the-fly.</p>

<p>VITROS Universal Wash Reagent</p>

<p>5.0L Container Box</p>

<p>Onboard liquid wash buffer for MircoWell immunometric bead washing; onboard capacity: 5.0L</p>

<p>Electrolyte Reference Fluid (EFR)</p>

<p>Reagent Bottles / Packs</p>

<p>Direct potentiometric measurement reference fluid for ISE Mirco Slides; Onboard: 800 Tests</p>

<p>Immuno-Wash Fluid (IWF)</p>

<p>Pre-Filled Wash Packs</p>

<p>Conditioning and wash fluid for MircoWell immune-incubation blocks; onboard: 300 Tests</p>

<p>Specialty Diluents &amp; Reconstitution Fluids</p>

<p>Vials / Assay-Specific Packs</p>

<p>Automated onboard reflex dilutions and off-board sample preparation matrices</p>

<p></p>

<p></p>

<p><strong>Diagnostic Assays &amp; Reagents</strong>:</p>

<p>The contractor shall supply the completed testing menu required by the facility, encompassing:</p>

<ol>
	<li><strong>XT MircoSlides &amp; Single MircoSlides:</strong></li>
</ol>

<ul>
	<li>Metabolic &amp; Renal Panels: <em>BUN/Urea, Creatinine, Electrolytes (Na+, K+, Cl-, CO2), Calcium, Phosphorus, Glucose</em></li>
	<li>Liver Enzymes &amp; Proteins: <em>ALT, AST, ALP, Total Bilirubin, Direct Bilirubin, Albumin, Total Protein</em></li>
	<li>Lipid Profiles: <em>Cholesterol, Triglycerides, HDL, LDL</em></li>
	<li>Enzymes &amp; Miscellaneous:<em> CK, Amylase, Lipase, LDH, Uric Acid</em></li>
</ul>

<ol>
	<li><strong>MircoTip Liquid Reagents:</strong></li>
</ol>

<ul>
	<li>Specific proteins (<em>e.g., CRP, hs-CRP, HbA1c, Ferritin</em>)</li>
	<li>Therapeutic Drug Monitoring (TDM) and Toxicology: (<em>e.g., Gentamicin, Vancomycin, Methotrexate, Digoxin, Valproic Acid)</em></li>
</ul>

<ol>
	<li><strong>MicroWell Chemiluminescence Immunoassays:</strong></li>
</ol>

<ul>
	<li>Cardiac Markers: <em>High-sensitivity Troponin I (hs-cTnI), NT-proBNP, CK-MB, Myoglobin</em></li>
	<li>Thyroid Panel: <em>TSH, Free T3, Free T4, Total T3, Total T4</em></li>
	<li>Infectious Disease &amp; Serology: <em>Hepatitis markers, HIV combo</em></li>
	<li>Reproductive Endocrinology &amp; Oncology: <em>Total B-hCG, PSA, CEA, CA_125, Ferritin, Folate, Vitamin D, Vitamin B12</em></li>
</ul>

<p><strong>&nbsp;&nbsp; Calibrators &amp; Quality Control Materials</strong>&nbsp;</p>

<ul>
	<li><strong>Barcoded Calibrator Kits:</strong> Multiplexed and single analyte calibrator kits matching the MircoSlide, MircoTip, and MircoWell Lots</li>
</ul>

<ul>
	<li><strong>Master Lot Data Disks / Barcodes:</strong> Machine-readable parameters providing calibration coefficients and curve parameters for up to 25 lots per assay</li>
	<li><strong>Routine Multi-level Controls: </strong>Daily tri-level liquid/lyophilized clinical chemistry, immunoassay, and specialty urine/cardiac control set</li>
</ul>

<p><strong>Bill of Material Control</strong></p>

<p>The Bill of Materials shall govern the specific items, part numbers, units of issue, and annual quantities to be delivered under this requirement. Narrative descriptions in this SOW define scope and technical intent only and shall not, by themselves, authorize delivery of items not expressly identified in the contract or applicable Bill of Materials</p>

<p>This notice of intent is not a request for competitive proposals. Sources interested in responding to this notice are required to submit a capability statement that includes management and technical data and price information, in sufficient detail and with convincing evidence that clearly demonstrates the capability to perform the required work. Capability statements shall not exceed five (8.5 x 11 inch) pages using a font size no smaller than 10-point. All capability statements received by the due date of this notice will be considered by the Government. A request for documentation or additional information will not be considered as an affirmative response or acceptance of the capability statement. A determination by the Government not to compete based on responses to this notice is solely within the discretion of the Government. Information received will be considered solely for the purpose of determining whether to conduct competitive procurement or to proceed with a sole source contract. Capability statements should also include the business size and cage code.</p>

<p>Capability statements are due by 2:00 PM Local Time, 30 November 2026. Capability statements shall be submitted by e-mail ONLY as a Microsoft Word or Adobe PDF attachment to the following address: curtis.e.cardoza.civ@us.navy.mil.</p>

[View original listing](https://sam.gov/opp/cbb325200338414fbb5e15e88e0e25f7/view)