# SAM #36C10X27Q0031

VA market research for nationwide low-temperature hydrogen peroxide sterilizers and related services

**Buyer:** VA CENTRAL OFFICE
**Posted:** November 19, 2026
**Respond By:** December 07, 2026
**Identifier:** 36C10X27Q0031
**NAICS:** 339113

The Department of Veterans Affairs is researching a nationwide supply of low-temperature hydrogen peroxide sterilizers for medical devices and 3D-printed items.
- **Government buyer:** Department of Veterans Affairs (VA), Enterprise Procurement Office (EPO), in conjunction with the Veterans Health Administration (VHA) Non-Expendable Equipment National Program.
- **OEM:** **STERIS Corporation** is the named manufacturer for the V-PRO MAX 2 system and listed related items. The VA may consider equivalent products.
- **Products:** Three V-PRO MAX 2 sterilizer configurations, specialty cycles, monitoring and shelf accessories, Vaprox HC sterilant, and a freestanding cabinet package. Part numbers are listed below; quantities are not specified.
- **Services:** Installation and deinstallation, pump service, maintenance and support plans, and service or customized training options. Part numbers and service terms are listed below.
- **Notable requirements under consideration:** FDA 510(k) clearance; hydrogen peroxide sterilant; sterilization capability for reusable robotic medical devices and 3D-printed items; validation for at least one dual-channel scope; a non-lumen quick cycle; freestanding configuration; multiple-door configuration as an option; at least a one-year warranty; and support, maintenance, and training.
- **Market-research information requested:** Technical literature demonstrating compliance, product and service pricing (including shipping and quantity discounts), country-of-origin information, and evidence of nationwide supply capability.
- **Procurement status:** This is a sources-sought market research notice, not a request for offers or a commitment to award.

### Description

<div>
  <p><strong>1.0 DESCRIPTION</strong></p>
  <p><strong>THIS IS A SOURCES SOUGHT NOTICE ONLY.</strong> This is not a solicitation for bids, proposals, proposal abstracts, or quotations. The Department of Veterans Affairs (VA) Enterprise Procurement Office (EPO), formerly the Strategic Acquisition Center (SAC), is issuing this Sources Sought Notice as a means of conducting market research to identify qualified sources with the capability and resources to meet the Veterans Health Administration's (VHA) Non-Expendable Equipment National Program requirement for Sterilizer Unit Low Temperature H2O2, with 3D printed items sterilization capabilities.</p>
  <p>The EPO, in conjunction with VHA, is seeking qualified sources capable of supplying the Steris Corporation® V-Pro Max 2 Sterilizer or equivalent products that satisfy the Salient Characteristics on an agency-wide basis. VA is contemplating the award of a single Requirements Contract with Firm-Fixed Price (FFP) orders IAW FAR 16.503, Requirements Contracts, to a supplier of this equipment. Respondents will be required to deliver complete Steris Corporation® V-Pro Max 2 Sterilizers to VA medical centers and facilities throughout the United States.</p>
  <p>The associated North American Industry Classification System (NAICS) code for this procurement is 339113 — Surgical Appliance and Supplies Manufacturing, and the associated size standard is 800 employees.</p>
  <p>The FAR Provision found at 52.204-7 requires that “The Offeror shall have an active Federal Government contracts registration in the System for Award Management (SAM) when submitting an offer or quotation.” You may access the SAM website at <a href="https://sam.gov/" target="_blank">SAM.gov | Home</a>. All respondents must be certified with the appropriate NAICS code on the SAM website. All Service-Disabled Veteran-Owned Small Business (SDVOSB) / Veteran-Owned Small Business (VOSB) respondents must be verified in the SBA database at <a href="https://www.sba.gov/veterans/#vetcert" target="_blank">https://www.sba.gov/veterans/#vetcert</a> at the time of submission.</p>
  <p>Submissions for this Sources Sought Notice shall be submitted by email no later than December 9, 2026, at 12:00 p.m. Eastern Time to the Contract Specialist and Contracting Officer at the following email addresses:</p>
  <ul>
    <li><a href="mailto:Joseph.Jeranek@va.gov">Joseph.Jeranek@va.gov</a></li>
    <li><a href="mailto:Kimberly.LeMieux@va.gov">Kimberly.LeMieux@va.gov</a></li>
  </ul>
  <p>Email responses shall include the following subject line: <strong>Response to Sources Sought Notice 36C10X27Q0031</strong>.</p>
  <p>This notice is for planning purposes only and does not constitute a commitment on the part of the Government to award a contract, nor does the Government intend to pay for any information submitted as a result of this notice. This notice is part of a continuous process for obtaining the latest information on the commercial status of the industry with respect to its current and near-term abilities. The information provided herein is subject to change and in no way binds the Government to solicit for, or award, a competitive contract. It is emphasized that this is a notice solely for planning and informational purposes. Respondents are advised that the Government is under no obligation to acknowledge receipt of the information received or provide feedback to respondents with respect to any information submitted. The Government may or may not issue a solicitation as a result of this notice. There is no solicitation available at this time.</p>
</div>

<div>
  <p><strong>2.0 SCOPE OF WORK</strong></p>
  <p>The Veterans Health Administration (VHA) Non-Expendable Equipment National Program has identified the Sterilizer Unit Low Temperature H2O2, with 3D printed items sterilization capabilities, as a candidate for a Veterans Affairs (VA)-wide (otherwise referred to as “national”) single Requirements contract award. The Low Temperature, Gaseous Plasma, Vaporized Hydrogen Peroxide (H2O2) Sterilizers are used for low-temperature sterilization of heat- and moisture-sensitive medical devices. Hydrogen peroxide is a known antimicrobial agent that oxidizes key cellular components within microorganisms, thereby destroying them. A low-temperature gaseous plasma sterilizer is an apparatus that uses vaporized hydrogen peroxide gas plasma to sterilize heat- and moisture-sensitive medical instruments and devices. The process involves injecting hydrogen peroxide vapor into a chamber, then applying an electrical field to create gas plasma. This plasma generates microbicidal free radicals that disrupt cellular components of microorganisms, killing them effectively. The process leaves behind harmless byproducts, water and oxygen, and is suitable for delicate equipment that cannot withstand high temperatures or humidity. Sterilization typically occurs at a temperature of less than 56°C, with process times of around 25 to 70 minutes depending upon cycle type.</p>
  <p>The following Contract Line Items (CLINs) are being considered:</p>
  <table>
    <thead><tr><th>CLIN</th><th>Manufacturer</th><th>Part Number</th><th>Description</th></tr></thead>
    <tbody>
      <tr><td>0001</td><td>STERIS Corporation</td><td>VP50001101</td><td>V-PRO MAX 2 STERILIZER 208-230V, 60HZ, REC SD EN</td></tr>
      <tr><td>0002</td><td>STERIS Corporation</td><td>VP50002101</td><td>V-PRO MAX 2 STERILIZER 208-230V, 60HZ, CAB SD EN</td></tr>
      <tr><td>0003</td><td>STERIS Corporation</td><td>VP50003101</td><td>V-PRO MAX 2 STERILIZER 208-230V, 60HZ, CAB DD EN</td></tr>
      <tr><td>0004</td><td>STERIS Corporation</td><td>VP0081</td><td>V-PRO MAX2 3X SPECIALTY CYCLES FACTORY INSTALLED</td></tr>
      <tr><td>0005</td><td>STERIS Corporation</td><td>VP0082</td><td>V-PRO MAX2 3X SPECIALTY CYCLES FIELD INSTALLED</td></tr>
      <tr><td>0006</td><td>STERIS Corporation</td><td>VP0083</td><td>INDEPENDENT MONITORING SYSTEM FOR V-PRO MAX 2</td></tr>
      <tr><td>0007</td><td>STERIS Corporation</td><td>VP0084</td><td>V-PRO WIDE SHELF</td></tr>
      <tr><td>0008</td><td>STERIS Corporation</td><td>VP0085</td><td>V-PRO MAX2 SPECIALTY CYCLE D FIELD INSTALLED</td></tr>
      <tr><td>0009</td><td>STERIS Corporation</td><td>VP0086</td><td>V-PRO MAX2 SPECIALTY CYCLE E FIELD INSTALLED</td></tr>
      <tr><td>0010</td><td>STERIS Corporation</td><td>VP0087</td><td>V-PRO MAX2 SPECIALTY CYCLE F FIELD INSTALLED</td></tr>
      <tr><td>0011</td><td>STERIS Corporation</td><td>PB011</td><td>VAPROX HC STERILANT (3 X 113 ML-PLASTIC BOTTLES IN FIBERBOARD BOX) RFID</td></tr>
      <tr><td>0012</td><td>STERIS Corporation</td><td>PB012</td><td>VAPROX HC STERILANT (4 X 29.6 ML-PLASTIC CUPS IN FIBERBOARD BOX) RFID</td></tr>
      <tr><td>0013</td><td>STERIS Corporation</td><td>SE6009810000105</td><td>1ST YEAR DEEP-VACUUM PUMP SVC V-PRO MAX 2 (3 PM)</td></tr>
      <tr><td>0014</td><td>STERIS Corporation</td><td>SE600962</td><td>STANDARD INSTALL LARGE HYDROGEN PEROXIDE STERILIZERS</td></tr>
      <tr><td>0015</td><td>STERIS Corporation</td><td>SE6009621</td><td>STANDARD DEINSTALL LARGE HYDROGEN PEROXIDE STERILIZER</td></tr>
      <tr><td>0016</td><td>STERIS Corporation</td><td>P146669300</td><td>CABINET PACKAGE SD FREE STANDING</td></tr>
      <tr><td>0017</td><td>STERIS Corporation</td><td>SE6009485</td><td>STANDARD INSTALL SEISMIC LOW TEMPERATURE STERILIZERS</td></tr>
      <tr><td>0018</td><td>STERIS Corporation</td><td>SE6009852000103</td><td>TOTAL CARE CONNECT V-PRO MAX 2 (2 PM)</td></tr>
      <tr><td>0019</td><td>STERIS Corporation</td><td>SE6009853000103</td><td>2 YEARS OF TOTAL CARE CONNECT V-PRO MAX 2 (2 PM)</td></tr>
      <tr><td>0020</td><td>STERIS Corporation</td><td>SE60098100003</td><td>LABOR CARE W/PM PARTS V-PRO MAX 2</td></tr>
      <tr><td>0021</td><td>STERIS Corporation</td><td>SE60098000283</td><td>2 YEARS OF LABOR CARE W/PM PARTS V-PRO MAX 2</td></tr>
      <tr><td>0022</td><td>STERIS Corporation</td><td>SE6009811000103</td><td>LABOR CARE V-PRO MAX 2</td></tr>
      <tr><td>0023</td><td>STERIS Corporation</td><td>SE6009811028103</td><td>2 YEARS OF LABOR CARE V-PRO MAX 2</td></tr>
      <tr><td>0024</td><td>STERIS Corporation</td><td>SE6009800048103</td><td>PREVENTIVE CARE V-PRO MAX 2</td></tr>
      <tr><td>0025</td><td>STERIS Corporation</td><td>SE6009800028103</td><td>2 YEARS PREVENTIVE CARE V-PRO MAX 2</td></tr>
      <tr><td>0026</td><td>STERIS Corporation</td><td>SE0000044</td><td>SERVICE TRAINING PROGRAM FOR V-PRO LOW TEMPERATURE, MENTOR, OH</td></tr>
      <tr><td>0027</td><td>STERIS Corporation</td><td>SE0000046</td><td>CUSTOMIZED TRAINING - 1 DAY / UP TO 5 TRAINEES</td></tr>
      <tr><td>0028</td><td>STERIS Corporation</td><td>SE0000047</td><td>CUSTOMIZED TRAINING - 2 DAYS / UP TO 5 TRAINEES</td></tr>
      <tr><td>0029</td><td>STERIS Corporation</td><td>SE0000048</td><td>CUSTOMIZED TRAINING - 3 DAYS / UP TO 5 TRAINEES</td></tr>
      <tr><td>0030</td><td>STERIS Corporation</td><td>SE61118</td><td>CUSTOMIZED TRAINING - 4 DAYS / UP TO 5 TRAINEES</td></tr>
      <tr><td>0031</td><td>STERIS Corporation</td><td>SE61119</td><td>CUSTOMIZED TRAINING - 5 DAYS / UP TO 5 TRAINEES</td></tr>
    </tbody>
  </table>
  <p>Respondents should identify a complete solution including associated accessories, as required for the system's full functionality.</p>
  <p>The following Salient Characteristics (SC) are being considered:</p>
  <ul>
    <li>CLINs 0001–0017 apply to the following SCs 1–8.</li>
    <li>CLINs 0018–0026 pertain to SC 9.</li>
    <li>CLINs 0027–0032 pertain to SC 10.</li>
  </ul>
  <table>
    <thead><tr><th>SC #</th><th>Salient Characteristics</th></tr></thead>
    <tbody>
      <tr><td>SC 1</td><td>Must be a freestanding configuration.</td></tr>
      <tr><td>SC 2</td><td>Must be capable of sterilizing reusable robotic medical devices/instruments.</td></tr>
      <tr><td>SC 3</td><td>Must be certified for sterilizing 3D printed items.</td></tr>
      <tr><td>SC 4</td><td>Must have FDA 510k clearance.</td></tr>
      <tr><td>SC 5</td><td>Must use H2O2/hydrogen peroxide for sterilant base.</td></tr>
      <tr><td>SC 6</td><td>Must have the option of multiple doors.</td></tr>
      <tr><td>SC 7</td><td>Must be validated to handle at least one dual-channel scope.</td></tr>
      <tr><td>SC 8</td><td>Must have a non-lumen quick cycle.</td></tr>
      <tr><td>SC 9</td><td>Shall provide a minimum 1-year warranty.</td></tr>
      <tr><td>SC 11</td><td>Must provide support and maintenance plans.</td></tr>
      <tr><td>SC 12</td><td>Must provide training.</td></tr>
    </tbody>
  </table>
  <p>For each product identified in the response (brand name and part number), the response must include descriptive literature demonstrating that the product meets or exceeds the SCs specified above.</p>
  <p>The Government's intent is to include all ancillary items necessary to ensure the equipment can function as designed by the OEM and as required. Respondents are encouraged to identify any additional STERIS accessory, service, or configuration that may be necessary or beneficial to the functionality of the contemplated system. These items must be clearly identified by brand name and part number.</p>
</div>

<div>
  <p><strong>Responses to this Sources Sought Notice shall include the following:</strong></p>
  <ul>
    <li>Full name and address of company.</li>
    <li>SAM Unique Entity Identifier (UEI).</li>
    <li>Business size and socioeconomic status, if applicable (e.g., SDVOSB, VOSB, WOSB, HUBZone, 8(a)).</li>
    <li>Manufacturer or distributor:
      <ul>
        <li>If distributor, provide the full name, business size, and address of the manufacturer.</li>
        <li>If distributor, provide evidence that your firm is currently an authorized distributor for the manufacturer of the products proposed, e.g., an authorized distributor letter with current date certified by the OEM.</li>
      </ul>
    </li>
    <li>Country of Origin designation for all products proposed.</li>
    <li>Describe the firm's ability to provide uninterrupted supply of products on a national scale.</li>
    <li>Technical literature clearly demonstrating that the proposed product(s) meet the identified minimum technical requirements, identifying the page number(s) where each requirement is met.</li>
    <li>Does respondent offer an annual service plan, Yes or No?
      <ul>
        <li>If yes, describe what the plan covers.</li>
        <li>Identify whether the plan covers software updates, parts repair/replacement, or both.</li>
        <li>Provide literature or other documentation describing the service plan.</li>
        <li>Identify whether service is provided by the OEM or a subcontractor.</li>
      </ul>
    </li>
    <li>Identify any additional STERIS product, accessory, service, or configuration that may be necessary or beneficial to the functionality of the contemplated systems. Include the applicable brand name and part number.</li>
    <li>Item pricing information for products, inclusive of flat-rate shipping. Include any quantity discounts, noting at what order quantity the Government should expect tiered price reductions, if any.</li>
    <li><strong>NOTE:</strong> In order for the Contracting Officer to determine whether a set-aside can be pursued, it is essential to provide pricing information. Without this information, the Contracting Officer will be unable to assess whether there is a reasonable expectation of receiving fair and reasonable pricing from socio-economic concerns.</li>
    <li>Does your firm anticipate any subcontracting opportunities for this requirement? If yes, identify the type and approximate scope of work that could be subcontracted.</li>
    <li>Identify any federal contract vehicles held by your firm through which your firm can provide this equipment.</li>
    <li>Are there any further standards or criteria VA should consider in a procurement action for this equipment?</li>
    <li>Are the Government's specifications unduly restrictive? If yes, identify the specific requirement(s) considered unduly restrictive and provide supporting rationale and recommended alternative language.</li>
    <li>Any additional information the Government should know prior to issuing a solicitation.</li>
    <li>Describe any minimum order quantities, geographic limitations, delivery constraints, lead times, or other limitations that could affect the firm's ability to support the requirement on a nationwide basis.</li>
  </ul>
</div>

<div>
  <p><strong>Additional Links:</strong></p>
  <p><a href="https://www.va.gov/opal/sac/index.asp" target="_blank">Learn more about EPO and its mission</a></p>
</div>

[View original listing](https://sam.gov/opp/1dece682ddad42fc9dfe4f70c5cb7cee/view)