# SAM #36C24727Q0119

Getinge VT-3050 Tunnel Washer with Removal and Installation Services

**Buyer:** VANCO 7
**Posted:** November 19, 2026
**Respond By:** November 30, 2026
**Identifier:** 36C24727Q0119
**NAICS:** 339112

The Department of Veterans Affairs is seeking a Getinge tunnel washer and associated installation services for the Atlanta VA Medical Center Veterinary Medical Unit.
- Government buyer: Department of Veterans Affairs, Atlanta VA Medical Center – Veterinary Medical Unit; Network Contracting Office 7 is identified in the notice.
- OEM: **Getinge**; the SOW names the Getinge VT-3050 tunnel washer, part number VT-3050.
- Equipment: One washer, with a 30-inch conveyor belt, intended to replace unreliable existing equipment supporting research operations. Listed exterior dimensions are 53 inches wide by 83 inches high by 26 inches deep; the unit is factory-assembled and tested but shipped disassembled for entry.
- Fit and safety requirements: The notice specifies a 49-by-78-inch wall opening, while the SOW specifies a 48-by-84-inch doorway; this difference should be verified. The washer must fit the existing footprint, and the wall-to-machine interface must avoid gaps that could create biohazard or cross-contamination risks. Narrower belts or shorter wash chambers are unacceptable.
- Included services: Inland freight; removal and disposal of the existing washer; final utility connections within five linear feet of the equipment connection points; delivery, unloading, on-site transport, leveling, assembly, startup, and one operator/supervisor training session.

### Description

<p>Please view the SOW attached.</p>

<p>Submit documentation with description for considerations of products.</p>

<p></p>

<p>Tunnel washer:</p>

<ul>
	<li><strong>Facility infrastructure constraints</strong> limit replacement equipment to the footprint of the existing tunnel washer.</li>
	<li><strong>Restricted wall opening dimensions</strong> of <strong>49&quot; wide x 78&quot; tall</strong> dictate the maximum equipment size.</li>
	<li><strong>Requires a non-standard 30&quot; conveyor belt tunnel washer</strong> because a standard 36&quot; conveyor belt unit cannot fit through the existing opening.</li>
	<li><strong>Smaller-than-30&quot; conveyor belts or shorter wash chambers are unacceptable</strong> due to operational and safety concerns.</li>
	<li><strong>Maintaining a proper wall-to-machine interface is critical</strong> to prevent gaps between the washer and wall opening.</li>
	<li><strong>Gaps would create biohazard risks</strong>, allowing potential cross-contamination between dirty and clean areas.</li>
</ul>

[View original listing](https://sam.gov/opp/4f684204f19c41329211bbd2501a8296/view)
