Army request for an expandable iWorx data acquisition system and LabScribe software

**Buyer:** MICC-Ft Drum
**Posted:** November 11, 2026
**Respond By:** November 26, 2026
**Identifier:** W911S227U0166
**NAICS:** 334516, 334510, 334519

The U.S. Army is seeking an expandable iWorx data acquisition system with extensive physiological measurement capabilities.
- **Government buyer:** U.S. Department of the Army, Mission and Installation Contracting Command, 419th Contracting Support Brigade, W6QM MICC–Fort Drum.
- **OEM:** **iWorx** is the named system manufacturer; **LabScribe** is the named software.
- **Requested system:** One iWorx expandable data acquisition system; quantity and part number are not specified. It must provide at least 18 channels, expand to at least 34 total channels, and allow multiple recorders to be linked.
- **Measurement and sensor capabilities:** Wireless ECG/EMG and 3-axis accelerometer support; expansion to 16 wired channels; ECG simulator; integrated pulse oximetry; spirometry, grip-force, and intensity sensors; and pre-calibrated temperature, force, spirometry, and blood-pressure sensors.
- **Other technical requirements:** Two built-in ±15 V low-voltage input channels; isolated constant-current high-voltage stimulator; iWire compatibility; integrated barometric pressure sensor; at least 16 digital I/O channels; at least one audio output channel; and USB-C power.
- **Included software and support:** Lifetime LabScribe software updates, an open site license, and unlimited online training at no additional cost.
- **Period of performance:** Not specified.

### Description

iWorx System Required System Specifications, Minimum 18-channel data recorder with the ability to expand to additional channels. Competing systems typically provide only 2-4 channels.	Ability to gang multiple recorders together for expanded data acquisition. Includes 2 channels of wireless ECG/EMG and 3-axis accelerometer capability, with expansion to 16 wired channels. Competing products generally provide only 1-2 channels. Includes an ECG simulator. Integrated Pulse Oximetry, spirometry, grip force, and intensity sensors designed for enhanced measurement accuracy.	Pre-calibrated temperature, force, spirometry, and blood pressure sensors, allowing immediate use with minimal setup requirements. Two built-in low-voltage input channels (+/-15V).	Built-in isolated constant current high-voltage stimulator.	Must be iWire compatible, allowing future expansion and integration of additional sensors and instrumentation.	Expandable to a minimum of 34 total channels.	Integrated barometric pressure sensor to improve spirometry accuracy without requiring separate external hardware.	Minimum 16 digital I/O channels.	Minimum 1 audio output channel.	Portable design capable of operation through a USB-C power connection. Includes lifetime free LabScribe software updates and an open site license. Includes unlimited online training at no additional cost. <br/><br/><br/><strong>Additional Links:</strong><br/><a href='https://toolbox-piee.eb.mil/' target='_blank'>Department of Defense Procurement Toolbox</a><br/><a href='https://piee.eb.mil/sol/xhtml/unauth/search/oppMgmtLink.xhtml?noticeId=W911S227U0166&noticeType=CombinedSynopsisSolicitation' target='_blank'>PIEE Solicitation Module Link for W911S227U0166</a><br/><a href='https://www.acq.osd.mil/asda/dpc/ce/cap/docs/piee/PIEE_Solicitation_Module_Vendor_Access_Instructions.pdf' target='_blank'>Registration Instructions for the PIEE Solicitation Module</a><br/><a href='https://pieetraining.eb.mil/wbt/xhtml/wbt/sol/index.xhtml' target='_blank'>Web Based Training for the PIEE Solicitation Module</a>