# SAM #36C26127Q0154

VA market research for Medtronic TruClear hysteroscopy instruments

**Buyer:** VA Network Contracting Office 21
**Posted:** November 05, 2026
**Respond By:** November 13, 2026
**Identifier:** 36C26127Q0154
**NAICS:** 423450, 339112

The Department of Veterans Affairs is researching gynecological hysteroscopy instruments for the Martinez VA Medical Center.
- **Government buyer:** Department of Veterans Affairs, Network Contracting Office 21, VA Northern California Health Care System, Martinez VA Medical Center; contracting specialist Shaun Owen.
- **OEM:** **Medtronic** TruClear equipment is the named product line; functionally equivalent products may also be proposed.
- **Requested products:**
  - 3 Mini TruClear Hysteroscopes (P/N 72204878)
  - 3 TruClear Handpieces (P/N 7209807)
  - 3 GYN Trays (P/N 72203004)
  - 1 Plus TruClear Hysteroscope (P/N 72204879)
- **Purpose and requirements:** Support uterine visualization and tissue removal, including treatment of intrauterine pathology. Equipment must provide continuous flow, be compatible with the TruClear system, and have FDA clearance; a one-year parts-and-labor warranty is required. The described system also calls for high-definition visualization and leak-resistant sealing.
- **Equivalent products:** Proposals should document technical and clinical equivalency and identify the manufacturer and country of origin; an authorized distributor letter is requested for alternatives.
- This is a market-research notice, not a solicitation.

### Description

THIS IS NOT A SOLICITATION
FOR INFORMATION AND PLANNING PURPOSES ONLY
1. Subject: Sources Sought, VA Northern California Health Care- Martinez VA Medical Center   Gynecological Hysteroscopy Surgical Instruments (TruClear or Equal)
This Sources Sought Notice seeks to identify qualified vendors capable of providing gynecological hysteroscopy surgical instruments equivalent to (or equal to) the TruClear product line.

2. General Information
Contracting Office:
Department of Veterans Affairs
Network Contracting Office (NCO 21)

Product Service Code (PSC): 6515   Medical & Surgical Instruments
NAICS Code: 339112   Surgical Appliance & Supplies Manufacturing
(Vendors may identify alternative NAICS if more appropriate.)
Point of Contact:
Shaun Owen, Contracting Specialist
Email: shaun.owen@va.gov

3. Description of Requirement
The Martinez VA Medical Center seeks capability responses from businesses able to supply Medtronic TruClear surgical equipment or functionally equivalent products to support gynecological hysteroscopy procedures. The requirement is for equipment used in visualization, diagnosis, and hysteroscopic tissue removal of intrauterine pathology, including polyps, fibroids, retained products of conception, and other uterine abnormalities.
The equipment shall provide:

High-definition hysteroscopic visualization of the uterine cavity;
Continuous-flow inflow and outflow capability to maintain uterine distention during procedures;
Compatibility with hysteroscopic tissue removal devices;
Minimally invasive access for diagnostic and operative hysteroscopy procedures;
Safe and efficient removal of intrauterine pathology through integrated visualization and tissue removal technology.
These items may be supplied as brand name (TruClear) or equal.

VA Medical Center Northern California
Hysteroscope Surgical instruments
Item #
Part Number/ Description
Qty
 Price 
 Extended Amount 
1
72204878 Hysteroscope Mini TruClear
3
Â 
Â 
2
7209807 HANDPIECE TRUCLEAR
3
Â 
Â 
3
72203004 GYN TRAY
3
Â 
Â 
4
72204879 Hysteroscope Plus TruClear
1
Â 
Â 





Â 
  SUBTOTAL with shipping included
Â 
Â 
Â 


4. Purpose of This Notice
The VA is conducting market research to:
  Determine industry capability and capacity;
  Identify potential sources, including Small Business concerns;
  Assess whether two or more qualified SDVOSBs or VOSBs are capable of performing.
  Inform the acquisition strategy.

5. Instructions to Respondents
Interested vendors shall submit a non binding capability statement including the following:
A. Business Information (required)
  Company name
  SAM.gov UEI
  Business size/status: SDVOSB, VOSB, WOSB, EDWOSB, HUBZone, 8(a), Small, Large
(As required in prior postings such as 36C26127Q0154 Sources Sought) 
  Confirm active SAM.gov registration
  If SDVOSB/VOSB, confirm certification through VetCert
B. Capability & Experience
  Provide documentation demonstrating capability to supply the required Gynecological items
  Include prior experience with VA, DOD, or private hospital surgical instrument supply
  Provide product literature, brochures, or cross reference sheets for brand name or equal items
C. GSA / Contract Information
  Indicate whether items are available under GSA/FSS/NASA SEWP/NITAAC, including contract number and expiration date
  State any open market availability
D. Product Data
  Indicate whether offering TruClear brand name or equal substitutes
  Provide equivalency documentation (technical specifications, clinical equivalency, FDA device class if applicable)
RESPONDENTS OFFERING EQUAL ALTERNATIVES: Respondents are to include the manufacturer of their equal item, the Country of Origin, and an authorized distributor letter.
E. Pricing Information
  Provide commercial pricing or discount structures (non binding)

6. Submission Details
Deadline: Response is due by 15:30 Pacific Time Friday, November 13, 2026.

Submission Method:
Email capability responses to:
shaun.owen@va.gov
Subject Line:
 Sources Sought Response   TruClear Surgical Instruments   [Company Name] 




7. Disclaimer
This Sources Sought/RFI is for market research only. It does not constitute a solicitation, does not obligate the Government, and is not a guarantee of future acquisitions. Responses will be used solely to inform the VA s acquisition strategy. Vendors responding to this notice are not guaranteed consideration for any future solicitation.

8. Attachments
None at this stage. A formal solicitation may follow.

Brand Name Item or Equal: 
Essential/significant physical, functional, or performance characteristics.  
Continuous-flow inflow and outflow capability to maintain uterine cavity distention.
Working channel designed to accommodate compatible TruClear tissue removal devices.
Leak-resistant sealing mechanism to minimize fluid loss during procedures. Designed for minimally invasive hysteroscopic procedures involving intrauterine pathology.
a) Compatibility   Must be compatible with the Medtronic TruClear hysteroscopic tissue removal system. Components must function together as an integrated system for visualization and intrauterine issue removal.
b) Dimensions    Per order specifications
c) Industry Standard   Device shall meet applicable FDA and industry standards for hysteroscopic visualization and tissue removal systems.
d) Purpose- Surgical procedures on patients.  
e) Governing Body or Organization   
FDA-cleared medical device.
Compliant with applicable healthcare regulatory requirements.
Complete generic identification     
Applicable model/make/catalog number-  See order
Manufacturer name    Medtronic
Warranty - One-year parts and labor with ongoing support on all equipment.
Installation/Training. n/a
Security- Patented and HIPAA compliant patient database with merge and sync capabilities across all systems
Per VAAR 811.104 and 811.105, I certify the following regarding the above information:
The salient characteristics listed above are essential to the Government s requirements.
To my knowledge, the restrictions listed above will not limit the acquisition to an item peculiar to one manufacture.

[View original listing](https://sam.gov/opp/e6a91224fb224ce39f2aecb5bafd1884/view)