# SAM #7-S176-Q-00012-00

Custom R&D box furnace for natural gas and hydrogen burner testing

**Buyer:** Argonne National Laboratory
**Posted:** October 29, 2026
**Respond By:** November 12, 2026
**Identifier:** 7-S176-Q-00012-00
**NAICS:** 333994

Argonne National Laboratory is seeking a custom furnace system for fuel-flexible burner research and testing.
- **Buyer:** UChicago Argonne, LLC, operator of Argonne National Laboratory (ANL), a U.S. Department of Energy laboratory.
- **OEMs and suppliers:** No furnace OEM or supplier is named. UChicago Argonne, LLC and Argonne National Laboratory are identified as the buyer/operator, not as furnace manufacturers.
- **Requested equipment:** One custom R&D box furnace system, with a modular rectangular burner bung, refractory and insulation, removable cooling tubes, optical windows, instrumentation ports, an exhaust flue with eductor, and three refractory pylon assemblies.
  - The burner bung seals an opening 36 inches wide by 72 inches high and adapts to different burner flange configurations; spare refractory/insulation material is also requested.
  - The three pylons are for radiant W-tube testing, radiant U-tube testing, and an indirect-firing tube configuration.
- **Performance and use:** Support direct- and indirect-fired burner testing with natural gas/hydrogen blends from 0–100%; up to 5 MMBtu/hr firing and 2,400°F bulk temperature. Commissioning includes at least two hours of operation at no more than 5 MMBtu/hr.
- **Services:** Design and engineering, fabrication and pre-testing, shipment and delivery, installation, and commissioning. The scope includes design reviews and ANL approval before fabrication, performance checks, and a commissioning report. ANL provides final utility connections and mounts the burner.
- **Site and notable requirements:** Installation and commissioning at ANL Building 362, Highbay. On-site work is subject to contractor safety requirements; work cannot begin until ANL issues a Notice to Proceed. The contractor is responsible for removing and disposing of debris resulting from its work.
- **Schedule:** Approximately six months from award through installation, commissioning, and closeout.

### Description

<p>Argonne National Laboratory (ANL) seeks a Supplier to design, fabricate, deliver, support installation, and commission a custom industrial furnace for R&amp;D testing of fuel-flexible burners using natural gas and hydrogen blends from 0&ndash;100% H₂.</p>

<p>The furnace shall support direct-fired and indirect-fired burner configurations and meet all requirements in the attached Statement of Work, including performance, facility interfaces, applicable codes, and safety requirements.</p>

<p>Award will be made on a&nbsp;<strong>Lowest Price Technically Acceptable (LPTA)</strong>&nbsp;basis. Technical acceptability will be evaluated on a pass/fail basis. Among responsible offerors determined technically acceptable and compliant with solicitation requirements, ANL will award to the offeror with the lowest evaluated price.</p>

<p>Offerors shall submit:</p>

<ol>
	<li>Completed and signed&nbsp;ANL-70 Request for Quotation.</li>
	<li>Technical compliance response addressing each Statement of Work requirement, with supporting evidence.</li>
	<li>Country of Origin information for the furnace and major components.</li>
	<li>Lead time from PO through final delivery,&nbsp;FOB Destination, Lemont, IL 60439, including major design, fabrication, delivery, and commissioning milestones.</li>
	<li>Completed and signed&nbsp;ANL-70B Representations and Certifications.</li>
	<li>Any proposed exceptions or deviations.</li>
</ol>

<p>Offers that do not meet mandatory requirements or do not provide adequate supporting documentation may be found technically unacceptable.</p>

<p>Country of Origin shall be provided in accordance with&nbsp;<strong>FAR 52.225-1, Buy American&mdash;Supplies</strong>. Please direct questions to the Contracting Officer. Thank you in advance for your participation.&nbsp;</p>

[View original listing](https://sam.gov/opp/a453b5522b5c4c73a6b3bf75f1d2cbf0/view)