# SAM #1240LP27SS0001

USFS Market Research for 45 Custom Outdoor-Rated Display Enclosures

**Buyer:** USFS Intermountain Region CSA 4
**Posted:** October 27, 2026
**Respond By:** November 06, 2026
**Identifier:** 1240LP27SS0001
**NAICS:** 332119, 332439, 332322, 337215

The U.S. Forest Service is gathering market information on 45 custom weather-resistant enclosures for electronic displays.
- **Government buyer:** U.S. Department of Agriculture, Forest Service, USDA-FS, CSA Intermountain 4.
- **Procurement status:** Request for Information (RFI) for market research and planning; it is not a solicitation or a commitment to purchase.
- **OEMs and vendors:** No manufacturers, OEMs, or vendors are named in the notice.
- **Requested product:** 45 custom outdoor-rated steel equipment enclosures for customer-provided six-character electronic display units.
  - Enclosure dimensions: approximately 14 in. high × 36 in. long × 12 in. deep; display dimensions: approximately 11 in. high × 33 in. long × 4 in. deep.
  - Construction equivalent to 14-gauge steel, painted inside and outside, with sealed protection equivalent to NEMA Type 4 or Type 12 for water and weather exposure.
  - Two rear mounting feet, each with two holes, spaced approximately 34 in. center-to-center.
  - Removable front cover that can be secured on top as a wind-stable sunshade, plus a removable interior panel for mounting the display.
- **Information sought:** Vendor capabilities, technical feedback, nonbinding pricing for 45 units, estimated production and delivery lead times, and commercially available products that could meet or be modified to meet the requirements.
- **Value:** The notice does not provide a budget or price. A rough planning estimate for the 45 custom enclosures is $22,500–$67,500.

### Description

<p><strong>REQUEST FOR INFORMATION (RFI)</strong><br />
<strong>Subject:</strong> Market Research &ndash; Custom Outdoor-Rated Equipment Enclosures<br />
<strong>Agency:</strong> U.S. Forest Service<br />
<strong>Type:</strong> Sources Sought / Request for Information (RFI)<br />
<strong>Purpose:</strong> This RFI is issued solely for information and planning purposes. This is <strong>not</strong> a solicitation and does <strong>not</strong> commit the Government to any future acquisition.</p>

<p><strong>1. INTRODUCTION</strong><br />
The U.S. Forest Service is conducting market research to identify capable vendors able to design, manufacture, and deliver <strong>custom outdoor-rated steel enclosures</strong> for electronic display equipment. The Government seeks industry input regarding capability, production lead times, materials, standards compliance, and potential manufacturing considerations.</p>

<p><strong>2. BACKGROUND</strong><br />
The Forest Service requires <strong>45 custom enclosures</strong> designed to house a six-character outdoor digital display unit. These enclosures must protect the device from weather, impact, and environmental exposure while providing specific mounting and sun‑shade functionality. All requirements are functional and performance‑based; no proprietary industrial design elements are required or included.</p>

<p><strong>3. OBJECTIVE OF THIS RFI</strong><br />
The Government seeks industry feedback on:<br />
&bull; Capability to manufacture enclosures meeting the dimensional, material, and performance requirements listed below.<br />
&bull; Potential challenges, recommended alternatives, or suggestions to improve manufacturability or durability.<br />
&bull; Estimated pricing ranges for planning purposes (not binding).<br />
&bull; Estimated production and delivery timelines.<br />
&bull; Identification of any commercially available products that meet or could be modified to meet the requirements.</p>

<p><strong>4. FUNCTIONAL REQUIREMENTS (SUMMARY)</strong><br />
Vendors responding to this RFI should describe their ability to meet the following <em>performance‑based</em> requirements:</p>

<p><strong>4.1 Enclosure Function</strong><br />
&bull; Outdoor‑rated steel enclosure similar in function to an industrial wireway or gutter box.<br />
&bull; Must accommodate a display unit measuring approximately <strong>11&Prime;H &times; 33&Prime;L &times; 4&Prime;D</strong>.<br />
&bull; Provide weather resistance and structural protection in an outdoor environment.</p>

<p><strong>4.2 Approximate Enclosure Dimensions</strong><br />
&bull; Exterior dimensions around <strong>14&Prime;H &times; 36&Prime;L &times; 12&Prime;D</strong>.</p>

<p><strong>4.3 Construction Requirements</strong><br />
&bull; Material equivalent to <strong>14‑gauge steel</strong>, painted interior and exterior.<br />
&bull; Environmental rating equivalent to <strong>NEMA Type 4 or 12</strong>.<br />
&bull; Fully sealed to prevent water and weather intrusion.</p>

<p><strong>4.4 Mounting Features</strong><br />
&bull; Two rear mounting feet, each with two mounting holes.<br />
&bull; Mounting hole spacing approximately <strong>34 inches center‑to‑center</strong>.</p>

<p><strong>4.5 Cover Design and Sun‑Shade Functionality</strong><br />
&bull; Removable front cover that can be mechanically secured on top of the enclosure to act as a sunshade.<br />
&bull; Shade cover must remain stable in typical outdoor wind conditions.<br />
&bull; Features such as studs, collars, clamps, or similar mechanical retention systems are acceptable&mdash;vendors may propose alternatives.</p>

<p><strong>4.6 Interior Mounting Panel</strong><br />
&bull; Removable panel suitable for mounting the customer‑provided electronic display.</p>

<p><strong>5. VENDOR RESPONSE REQUESTED</strong><br />
Interested vendors are invited to submit the following information:</p>

<ol>
	<li><strong>Company Information:</strong><br />
	&bull; Name, address, point of contact, DUNS/UEI, small business status.</li>
	<li><strong>Capability Statement:</strong><br />
	&bull; Description of relevant manufacturing experience.<br />
	&bull; Ability to meet or exceed the functional requirements listed above.</li>
	<li><strong>Technical Feedback:</strong><br />
	&bull; Any potential challenges with the requirements.<br />
	&bull; Recommendations to reduce cost or improve durability while maintaining function.</li>
	<li><strong>Rough Order of Magnitude (ROM) Pricing:</strong><br />
	&bull; Non-binding estimate for a quantity of <strong>45 units</strong>.</li>
	<li><strong>Estimated Lead Time:</strong><br />
	&bull; Production timeline from receipt of specifications to delivery.</li>
	<li><strong>Product Literature or Photos (if applicable):</strong><br />
	&bull; Examples of similar enclosures previously manufactured.</li>
</ol>

<p><strong>6. RESPONSE INSTRUCTIONS</strong><br />
Responses should be submitted electronically in PDF or Word format.<br />
This RFI is solely for market research; submission does not guarantee future solicitation or contract award.</p>

<p><strong>7. DISCLAIMER</strong><br />
This RFI does <strong>not</strong> constitute a solicitation and shall not be construed as a commitment by the Government. All information received is strictly voluntary and will be used for planning purposes only.</p>

<p><strong>VENDOR RESPONSE FORM</strong><br />
<strong>Request for Information (RFI): Custom Outdoor-Rated Equipment Enclosures</strong></p>

<p><strong>Section 1 &ndash; Vendor Information</strong></p>

<ol>
	<li>Company Name: ______________________________________________</li>
	<li>Address: _____________________________________________________</li>
	<li>Point of Contact (Name &amp; Title): _______________________________</li>
	<li>Email: ____________________________ Phone: ____________________</li>
	<li>UEI / DUNS Number: __________________________________________</li>
	<li>Business Size (check all that apply):<br />
	&bull; ☐ Large Business<br />
	&bull; ☐ Small Business<br />
	&bull; ☐ HUBZone<br />
	&bull; ☐ Woman-Owned<br />
	&bull; ☐ Veteran-Owned / SDVOSB<br />
	&bull; ☐ Other: _________________________________________________</li>
</ol>

<p><strong>Section 2 &ndash; Capability Statement</strong></p>

<ol>
	<li>Describe your company&rsquo;s capability to manufacture outdoor-rated enclosures meeting the performance requirements summarized in the RFI:</li>
</ol>

<ol>
	<li>Provide examples of similar work or relevant past performance:</li>
</ol>

<p><strong>Section 3 &ndash; Technical Feedback</strong></p>

<ol>
	<li>Identify any requirements that may present challenges or require clarification:</li>
</ol>

<ol>
	<li>Recommend any alternative materials, mounting features, or design approaches that may improve durability, cost efficiency, or manufacturability:</li>
</ol>

<p><strong>Section 4 &ndash; Estimated Pricing (ROM &ndash; Non‑Binding)</strong><br />
Provide an estimated cost range for manufacturing a quantity of <strong>45 enclosures</strong>.<br />
&bull; Unit Price Estimate: ___________________________________________<br />
&bull; Total Estimate: _______________________________________________</p>

<p><strong>Section 5 &ndash; Production Lead Time</strong><br />
Please provide estimated timelines for:<br />
&bull; Prototype or sample unit (if applicable): ________________________<br />
&bull; Full production: ______________________________________________<br />
&bull; Delivery of all units: __________________________________________</p>

<p><strong>Section 6 &ndash; Additional Information</strong><br />
Include any product brochures, enclosure photos, technical drawings, or configuration options related to similar enclosures your company provides.</p>

<p><strong>Section 7 &ndash; Certification</strong><br />
I certify that the information provided in this response is accurate to the best of my knowledge.</p>

<p>Name: ___________________________ Title: _______________________<br />
Signature (if applicable): _____________________ Date: ___________</p>

[View original listing](https://sam.gov/opp/8d0e6516010e45cc9fc7597ccdbc7c86/view)
