# SAM #FA4809AWHVAC

Room 2821 Split Heat Pump Replacement and Interior Restoration

**Buyer:** 4th Consolidated Squadron, ACC
**Posted:** October 21, 2026
**Respond By:** October 28, 2026
**Identifier:** FA4809AWHVAC
**NAICS:** 238220

The U.S. Air Force is seeking HVAC replacement and interior restoration work in Room 2821 at Seymour Johnson Air Force Base.
- Government buyer: U.S. Air Force, 4th Civil Engineer Squadron (4 CES), supported by the 4th Contracting Squadron (4 CONS), Seymour Johnson Air Force Base.
- **OEM:** American Standard is named as the heat-pump manufacturer; an approved technical equivalent is permitted. No resellers or other vendors are named.
- Products, each quantity 1: a 2-ton (24,000 BTU), minimum 14 SEER split heat pump with 10 kW auxiliary heat; a new insulated copper refrigerant line set; and a commercial digital/programmable thermostat. No part numbers are specified.
- Work includes removing and disposing of the existing HVAC unit, installing and commissioning the replacement system, and repairing, priming, and painting affected interior surfaces to match existing finishes.
- Notable requirements include final completion within 10 business days of the start of on-site work, a one-year workmanship warranty, a $10,000 bond, base-access coordination, and daily cleanup. Testing covers heating, cooling, auxiliary heat, defrost cycles, and blower performance.
- The contractor provides labor, supervision, tools, materials, equipment, transportation, and incidentals. Quotes are evaluated on price, technical merit, and past performance.

### Description

<p>The Contractor shall provide all personnel, management, supervision, tools, materials, equipment, transportation, and incidentals necessary to remove, furnish, and install a complete split heat pump system and perform associated interior architectural restoration in Room 2821 at Seymour Johnson Air Force Base.</p>