# SAM #N3904027Q0010

Rental of an oil-free 800 SCFM low-pressure air compressor system for Naval Base Point Loma

**Buyer:** Portsmouth Naval Shipyard
**Posted:** October 16, 2026
**Respond By:** October 21, 2026
**Identifier:** N3904027Q0010
**NAICS:** 532490

The U.S. Navy is seeking a short-term rental of an oil-free, high-volume compressed-air system for Naval Base Point Loma.
- **Government buyer:** Department of the Navy, Portsmouth Naval Shipyard (PNSY), Contracting Code 410; related data deliverables reference Code 230 and Project TSZM. The equipment will be used at Naval Base Point Loma in San Diego, California.
- **OEMs and vendors:** No OEM, manufacturer, or rental vendor is named. Offerors must identify their proposed manufacturer and model and provide technical information showing compliance.
- **Equipment package:** One 200 HP, 800 SCFM low-pressure air compressor (LPAC), with 100% oil-free air; one 1,000-gallon receiver tank; one 800 SCFM desiccant dryer; one distribution manifold; 250 feet of 3-inch air hose; 200 feet of power cable; and operating/safety controls, fittings, adapters, and remote emergency-stop equipment and cabling.
- **Key specifications:** Compressor discharge output must meet the 800 SCFM requirement, with a 115 PSIG set point and maximum system pressure of 125 PSIG. The package must support outdoor operation from -10°F to 110°F. The dryer must provide a -40°F pressure dew point. Compressor power is 460 VAC on one circuit, with a maximum operating amperage of 400A; the dryer uses 120 VAC, single phase, 20A.
- **Installation and operation:** The compressor will be used as needed. The Government provides suitable electrical sources; the contractor makes final electrical connections. The contractor must be prepared to provide and route up to 1,500 feet of emergency-stop cabling. The system includes a 3-inch manifold with at least six 1.25-inch outlets, isolation valves, and 150 PSI minimum working-pressure air hose and receiver components.
- **Services and deliverables:** Rental includes freight, equipment start-up and commissioning, base-period operator training, preventive maintenance, weekly inspections, repair support, and technical/data deliverables. Repair service is required within 12 hours of notification; if equipment cannot be returned to service within 24 hours, a replacement must be provided at no additional charge. Training is not required during the option period.
- **Rental duration:** Five-week base rental with a two-week option. No named OEM part numbers are provided; data deliverables use the listed DI identifiers in the line items below.

### Description

<p>Amendement 0001 is isuued to provide responses to vendor questions received om October 19, 2026. Please see the responses below, provided in <strong>bold:</strong></p>

<p></p>

<p>Question:&nbsp;Will the compressor operate continuously, 24 hours per day, seven days per week? If not, what are the estimated operating hours per week?</p>

<p><strong>Answer:The project will use this compressor whenever is needed for as long as needed.</strong></p>

<p>Question:&nbsp;Is the required 800 SCFM measured at the compressor discharge or at the point of use after accounting for dryer purge consumption?</p>

<p><strong>Answer: The discharge of the compressor</strong></p>

<p>Question:&nbsp;Please confirm the government will provide suitable electrical sources for both the compressor and dryer. Who is responsible for making the final electrical connections?</p>

<p><strong>Answer: The government will provide suitable electrical sources, however, the contractor will be responsible for making the final connection.</strong></p>

<p>Q:&nbsp;Can the government provide an estimated routing distance or layout for the remote emergency-stop cable so we can price the installation accurately?</p>

<p><strong>Answer:</strong> <strong>The contractor shall be prepared to provide and route up to 1500 ft of e stop cabling.</strong></p>

<p>Q:&nbsp;CLIN 0003 covers training during the five-week base period. Should any training required during the optional extension be included in CLIN 1001?</p>

<p><strong>Answer: No training required for the optional extension CLIN 1001</strong></p>

<p></p>

<p><strong>Rental of one (1) Electric 800 CFM Low Pressure Air Compressor (oil free) Naval Base Point Loma, San Diego, CA &nbsp;PLOMA</strong></p>

<p>Portsmouth Naval Shipyard (PNSV) is seeking to rent one (1) Electric 800 CFM Low Pressure Air Compressor (oil free). The Statement of Work (SOW) outlines the specifications that meet the essential requirements for the procurement of rental equipment necessary to to establish a tool air system. The application for this equipment is located at Naval Base Point Loma, San Diego, CA &nbsp;PLOMA.</p>

<p><strong>Solicitation Number:</strong> N3904027Q0010</p>

<p><strong>Response Deadline:</strong> October 21, 2026, at 12:30 PM (EST)</p>

<p><strong>POC:</strong> Bob Watters, robert.n.watters.civ@us.navy.mil</p>

<p><strong>Required Delivery Date/Period of Performance:</strong></p>

<p>Base period: 11/02/2026 - 12/06/2026 (5 weeks)</p>

<p>Option Period 1: 12/07/2026 - 12/20/2026 (2 - weeks)</p>

<p><strong>Place of Performance: </strong>Naval Base Point Loma, San Diego, CA PLOMA</p>

<p></p>

<p><strong>METHOD OF PROPOSAL SUBMISSION</strong></p>

<p>Offers shall be emailed. All responsible sources may submit a quote which shall be considered by the agency.</p>

<p>System for Award Management (SAM): Vendors must be registered in the SAM database to be considered for award.</p>

<p>Registration is free and can be completed on-line at http://www.sam.gov/.</p>

<p>All quotes shall include the embedded Request for Quote (RFQ). All quotes must have the highlighted sections completed.</p>

<p>Please make sure to include all technical data sheets and information relating to the rental equipment.</p>

<p></p>

<p></p>

[View original listing](https://sam.gov/opp/71b8fa0947f14bd0a6fcdfdf71fd0d97/view)