# SAM #N6817127QN003

USS Oscar Austin MID Deployment Voyage Repair and Gas Turbine Module Changeout Support

**Buyer:** NAVSUP FLC Sigonella Naples
**Posted:** October 09, 2026
**Respond By:** October 15, 2026
**Identifier:** N6817127QN003
**NAICS:** 488390, 336611

NAVSUP Fleet Logistics Center Sigonella is seeking deployment voyage repair work for USS Oscar Austin (DDG 79) in Rijeka, Croatia.
- **Government buyer:** U.S. Department of the Navy, NAVSUP Fleet Logistics Center Sigonella (FLCSI), Site Naples / NAVSUP Fleet Logistics Center Naples; FDRMC Naples supports the repair specification and FDRMC Code 130 QA provides the qualification checklist. The solicitation lists Antonella De Fraia Frangipane as the point of contact.
- **OEMs named:** **Dover Fluid Management Inc.** (AFFF pump), **Dover** (steam-jacketed kettles), and **Dover Steam** (steam-jacketed kettle). No reseller or repair-service vendor is identified by name.
- **Requested repair services:** One lot of MID Deployment Voyage Repair under specification NAPL-007-27, including crane and rigging to replace one AFFF pump; installation of one seawater check valve; insulation and lagging work at specified ship locations; hydrostatic and operational tests for three steam-jacketed kettles; pumping and disposal of up to 10,000 gallons of HAZMAT liquids; and crane, forklift, rigging, and scaffolding support for a gas turbine module changeout.
- **Notable quantities and requirements:** The gas turbine changeout support includes 60 crane lifts (up to 20,000 lb each), 25 forklift lifts (up to 15,000 lb each), 240 rigging man-hours, and an enclosed equipment/material area of at least 400 sq. ft. and 9 ft. high. The kettle tests are at 45 PSIG for at least 30 minutes, with no leakage allowed. The check valve and affected piping must be operationally tested at normal system pressure with no leakage.
- **Quality and qualification requirements:** The checklist calls for applicable quality-system documentation, calibration records, qualified inspector lists, Marine Chemist/Gas Free Engineer certifications, coatings-inspector qualifications and applicable QP-1 certification, welding/brazing and NDT qualifications and procedures, and a draft Test and Inspection Plan.
- **Performance and pricing:** Work is to be performed in Rijeka, Croatia, over approximately 16 calendar days. The solicitation requests firm-fixed-price quotations and identifies Lowest Price Technically Acceptable selection. The supplied price worksheet shows zero personnel, labor hours, and costs, so it does not establish a contract value.

### Description

<p>USS SHIP -&nbsp;MID Deployment Voyage Repair (MDVR)</p>

[View original listing](https://sam.gov/opp/24775d026cdc4accb1264bb4be0e75d8/view)