# Missouri BUYS #MODOT 0000000425SL,1

MoDOT Cuba Facility: Replacement of 13 Sectional Overhead Doors

**Posted:** October 05, 2026
**Respond By:** October 28, 2026
**Identifier:** MODOT 0000000425SL,1
**NAICS:** 238290

MoDOT is seeking a complete labor-and-materials replacement of overhead doors at its Cuba Maintenance Facility.
- **Government buyer:** Missouri Department of Transportation (MoDOT), Procurement Business Unit 31-MODOT Transportation; project contact named Logan Wilbers.
- **Scope and quantity:** Remove and dispose of the existing equipment, then supply and install 13 electric sectional overhead doors, each 12 ft × 12 ft, with operators and related hardware.
- **Door OEMs:** **C.H.I. Overhead Doors** Model 3216 is the basis of design; **Raynor** ThermaSeal TM 175 is an acceptable alternate.
- **Operator and component OEMs:** **LiftMaster** Logic 5.0 commercial operators and LC36M monitored light curtains are specified references; **Overhead Door Corp.** RHX is specified for front-of-hood mounting or equal; **Canimex** is named for a garage-door safety stopping bottom bracket. The documents do not identify an awarded vendor.
- **Included items:** Each door is specified with a trolley operator, one-button remote, 24 in × 7 in glazed opening, monitored light curtain, safety stop, springs, weather seals, three-button control station, tracks, and components needed for a complete system. The operator specifications also describe trolley, side-mount jackshaft, and front-of-hood configurations; quantities for the latter configurations and some accessories are not separately stated.
- **Notable requirements:** Insulated 2-inch door sections with R-value 16, 80 mph minimum wind-load design, galvanized tracks and hardware, and 25,000-cycle springs. Operators require safety devices, emergency manual operation, and at least a one-year manufacturer warranty. Contractor must take final measurements onsite, attend the mandatory site visit, and self-perform at least 10% of the work.
- **Schedule and warranties:** Work is to start under the Notice to Proceed and finish by the solicitation’s stated completion deadline. A one-year correction period and a one-year warranty for electric operating equipment are specified.

### Description

MoDOT is seeking bids for the labor and materials required to replace thirteen 12′ × 12′ sectional overhead doors at its Cuba Maintenance Facility. Bids may be submitted electronically through MissouriBUYS or by mail, UPS, or FedEx; bidders submitting a hard-copy bid must email the buyer of record five business days before the bid closing. Attendance at a site visit is mandatory for bids to be accepted. The solicitation also includes specifications for doors, electric operators, and related submittals and closeout requirements.

[View original listing](https://ewqg.fa.us8.oraclecloud.com/fscmUI/redwood/negotiation-abstracts/view/abstractlisting?prcBuId=300000005255687)