# Missouri BUYS #MODOT 0000000425SL

MoDOT replacement of 13 sectional overhead doors and operators

**Posted:** October 02, 2026
**Respond By:** October 27, 2026
**Identifier:** MODOT 0000000425SL
**NAICS:** 238290

The Missouri Department of Transportation (MoDOT) is seeking a complete replacement of overhead doors and related operators at its Cuba Maintenance Facility.
- **Buyer:** State of Missouri, Missouri Department of Transportation (MoDOT), identified as 31-MODOT TRANSPORTATION; facility in Cuba, Crawford County. The solicitation contact is Logan Wilbers.
- **Scope and quantity:** Supply and install 13 sectional overhead doors, each 12 feet by 14 feet, including operators and components needed for a complete working system. Remove and dispose of existing doors and operators and take final measurements.
- **Door OEMs:** **C.H.I. Overhead Doors Model 3216** is the specified basis of comparison; **Raynor ThermaSeal TM 175** is also identified as an acceptable manufacturer.
- **Door requirements:** Insulated, glazed 2-inch sections with R-16 insulation, roof-line tracks, electric operation, and a minimum 80-mph wind-load rating. Each door includes one 24-by-7-inch insulated-glass opening, tracks, hardware, springs, weather seals, and factory finish.
- **Operators and safety equipment:** Operator configurations include trolley, side-mounted jackshaft, and front-of-hood types where required. Specifications reference **LiftMaster Logic 5.0 Commercial Door Operator** or equal and **Overhead Door Corp. Model RHX** for the front-of-hood configuration. Provide a **LiftMaster LC36M 36-inch monitored light curtain** and **Canimex torque-force safety stopping bottom bracket**, along with safety stops, controls, and one-button remotes. Operator and accessory quantities are not separately stated.
- **Installation and completion:** Provide labor, equipment, materials, adjustments, electrical coordination, and an operation and maintenance demonstration. The operator installer makes the final electrical connection; the electrical contractor provides power. The contractor must self-perform at least 10% of the work and complete the project through final acceptance.
- **Other requirements:** Operators require a minimum one-year manufacturer warranty; the door specifications also call for a one-year correction period after completion.

### Description

MoDOT is seeking a material and labor bid to replace thirteen 12’ × 14’ sectional overhead doors at its Cuba Maintenance Facility. Bids may be submitted electronically through MissouriBUYS or by mail, UPS, or FedEx. Bidders planning to submit a hard-copy bid must email the buyer of record five business days before bid closing. Attendance at a site visit is mandatory for bids to be accepted.

[View original listing](https://ewqg.fa.us8.oraclecloud.com/fscmUI/redwood/negotiation-abstracts/view/abstractlisting?prcBuId=300000005255687)