# PIEE #W911S227U0010

Request for Two Qualitech Thermal Arc Sound Attenuation Booths

**Buyer:** MICC-Ft Drum
**Posted:** October 02, 2026
**Respond By:** October 13, 2026
**Identifier:** W911S227U0010
**NAICS:** 333415, 332322, 332311

W6QM MICC-Fort Drum is seeking two sound attenuation booths for McAlester Army Ammunition Plant (MCAAP), with Qualitech identified as the OEM.
- Buyer and destination
  - Buyer: W6QM MICC-Fort Drum, supporting McAlester Army Ammunition Plant (MCAAP).
- **OEM:** Qualitech; similar or equal products may be offered.
- Products requested
  - One booth, model QT100118128TA, measuring 77.5 × 102.5 × 116 inches.
  - One booth, model QT77102116TA, measuring 100 × 118.5 × 128 inches.
- Required booth features
  - Parts and hardware for erection in two halves; 18-gauge galvanized flat panels, a single-slope roof, Rockwool insulation, and a galvanized perforated interior liner.
  - Doors, hardware, switches, internal bracing, and provisions for floor anchoring.
  - Internal ventilation plenum, welding-arm offset and cutout, and duct-transition opening.
- Technical submittals and scope boundaries
  - MCAAP Engineering review and approval of a detailed technical description addressing each required feature is needed before award; detailed drawings are also required.
  - Approval drawings are requested, along with 3D models in SolidWorks, IGES, or STEP format after award.
  - On-site installation, mounting, building air, exhaust fans, lights, and other auxiliary components are provided by others or MCAAP.

### Description

Amendment 0001 CLIN Correction.  Thermal Arc Booth Salient Characteristics MCAAP Engineering will verify and validate the proposal from the vendor prior to award.Scope:  Thermal Arc Sound Attenuation Booth. Includes all necessary parts and hardware for a completely erected (in 2 halves) Thermal Arc Booth.Item/Model #: QT100118128TA or similar. 1 EAProduct Description:77.5-inch x 102.5-inch x 116-inch Booth.Includes all necessary parts and hardware for a completely erected (in 2 halves) Thermal Arc Booth.18ga galvanized flat panel construction with single slope style roof. Rockwool insulation enclosed in between the 3-inch-deep exterior wall panel and the galvanized, perforated interior liner. Unit is to be assembled and shipped with doors loose. Door hardware and switches included.All onsite installation, mounting, etc. are by others. All auxiliary components (exhaust fan, lights, switches, etc.) are supplied and installed by others.Model: Qualitech thermal arc sound attenuation booth model QT77102116TA or similar. 1 EA.Product Description:100-inch x 118.5-inch x 128-inch Booth.Includes all necessary parts and hardware for a completely erected (in 2 halves) Thermal Arc Booth.18ga galvanized flat panel construction with single slope style roof. Rockwool insulation enclosed in between the 3-inch-deep exterior wall panel and the galvanized, perforated interior liner. Unit is to be assembled and shipped with doors loose. All onsite installation, mounting, etc. are by others. All auxiliary components (exhaust fan, lights, switches, etc.) are supplied and installed by others.Thermal Arc Booth Dimensional specs:102.5-inch overall outer dimension entrance to exit face.86.5-inch overall outer dimension of booth depth.36.5-inch outer dimension of front booth section depth.20-inch outer dimension of back booth section depth including the welding arm offset.44-inch outer dimension wide by 9-inch outer dimension deep welding arm offset centered on the back booth section with a 114-inch tall and 26-inches wide cut out.30-inch door gap between the front and back booth sections.10-inch gap on the top between the front and back booth sections for monorail fed items.120-inch minimum interior height.3-inch-deep exterior wall panels.18-inch x 18-inch hole for duct transition piece located on the front booth section above the internal plenum.Features: Internally mounted entrance door that swings towards the front.Externally mounted exit door that swings towards the front.Door hardware and switches including cylinders and controls.Internal plenum in the front booth section for ventilation.Welding arms offset and cut out.18ga galvanized flat panel construction with single slope style roof.Rockwool insulation.Galvanized perforated interior liner. Mounting plates for floor anchoring.Anchoring hardware. Internal bracing.MCAAP to provide: Building air. Installation. Auxiliary components.DETAILED DESCRIPTION REQUIRED PRIOR TO AWARD: The MCAAP Engineering Support Division will validate and verify/approve the contractor listed equipment concept before award is granted. In order to meet this review requirement, the offeror shall submit with their proposal a detailed technical description of the thermal arc booth. The offerors description submittal shall account for each one of the required product features located in this qualifying statement. Conceptual drawings that are not detail as built drawings are required for submittal with the detailed description.Approval drawing(s) is/are requested. 3D models requested can be in native SolidWorks format, IGES, and/or STEP within two weeks after award.

[View original listing](https://piee.eb.mil/sol/xhtml/unauth/search/oppMgmtLink.xhtml?noticeId=W911S227U0010&noticeType=CombinedSynopsisSolicitation)