# SAM #W912HY27BA001

Emergency streambank erosion protection at the Mary Rhodes Pump Station

**Buyer:** Galveston District
**Posted:** October 01, 2026
**Respond By:** October 13, 2026
**Identifier:** W912HY27BA001
**NAICS:** 237990

The U.S. Army Corps of Engineers is seeking industry capability information for emergency riverbank protection at the Mary Rhodes Pump Station in Bay City, Texas.
- **Government buyer:** U.S. Army Corps of Engineers, Galveston District; no specific office is identified.
- **Opportunity:** Sources-sought market research for work under CAP Section 14, not a formal solicitation.
- **Requested service:** Rebuild and slope approximately 2,015 feet of riverbank to protect the pump station from Lower Colorado River erosion.
  - Install longitudinal launchable-stone toe protection along the project length, using at least 16.7 tons of stone per linear foot.
  - Install riprap tiebacks extending approximately 50 feet landward from the top of the bank, spaced approximately 250 feet apart.
  - The approximate height from the bottom of toe protection to the top of the tiebacks is 44 feet.
- **Products, quantities, and vendors:** No product part numbers or named OEMs, vendors, or suppliers are specified. Stone quantities are stated as a minimum rate per linear foot; total quantity is not provided.
- **Performance timing:** No overall period of performance is specified; work is to begin within 10 calendar days after notice to proceed.

### Description

<p>Please see attached for details about this procurement.&nbsp;</p>

[View original listing](https://sam.gov/opp/83f1583953b5407aa531f696e36c6f19/view)