# SAM #36C24626Q1102

VA Richmond Medical Center seeks Evoqua Deionized Water System Service and related parts

**Buyer:** Veterans Affairs National Cemetery Administration
**Posted:** September 22, 2026
**Respond By:** September 24, 2026
**Identifier:** 36C24626Q1102
**NAICS:** 561990, 811219

This opportunity is for Evoqua Deionized Water System Service at the Richmond VA Medical Center, focusing on laboratory water purity and system reliability.
- Government Buyer:
  - Department of Veterans Affairs, Network Contracting Office 6, Richmond VA Medical Center Pathology and Laboratory Medicine-Administrative
- OEMs and Vendors:
  - Evoqua (primary OEM for all parts and services)
- Products Requested:
  - Evoqua filter cartridges (W2T159701, W2T918450)
  - Evoqua UV lamp (W2T850795), quartz sleeve (W2T850799), O ring (W2T850802), washer (W2T850803)
  - Evoqua NIL-8 test strips (PAA: W2T934633, H2O2: W2T934634), NIL-8 sanitizer (W2T936744)
  - Evoqua SDI mixbed tank (W5TDIMB10360FSP), SDI react carbon tank (W5TDIRAC0360FSP)
- Services Requested:
  - Recurring preventive maintenance (parts & labor)
  - Conductivity readings, flow and pressure adjustments, pump inspections
  - SDI testing, prefilter maintenance, loop cleaning and sanitization
  - Fuel/energy surcharge for service visits
- Unique Requirements:
  - All replacement parts must be Evoqua OEM
  - Services must ensure regulatory compliance and laboratory water quality standards
  - Focus on maintaining high-purity deionized water for laboratory use
- Notable Details:
  - Specific Evoqua part numbers provided for all consumables and replacement items
  - Service scope includes both technical maintenance and consumable supply
  - No explicit contract duration or option years mentioned; annual preventive maintenance implied

### Description

The Department of Veterans Affairs, Network Contracting Office (NCO) 6 on behalf of Richmond VAMC is conducting Market Research through this source sought notice to help determine the availability of qualified Businesses, capable of providing Evoqua Deionized Water System Service that meet the following:

Salient Characteristics   Evoqua DI Water System Components & Services
Service & Maintenance Items
W3TSP3006   Fuel/Energy Surcharge
Fixed surcharge applied per service visit.
Supports technician travel and operational energy costs needed to perform DI system maintenance.
W3TSP3011   PM Contract Recurring (Parts & Labor)
Provides recurring annual preventive maintenance for the DI system.
Includes all required labor and OEM parts.
Ensures system reliability and compliance with regulatory water-quality requirements.
W3TSP4346   Conductivity Readings & Record Data
Contractor performs conductivity testing of DI water output.
Readings ensure water purity meets laboratory standards.
W3TSP4408   Adjust Flows and/or Pressures
Technician adjusts internal system flows and pressures.
Ensures optimal DI production performance and protects downstream equipment.
W3TSP4417   Inspect Pumps
Inspection and verification of pump condition and operation.
Identifies wear, misalignment, inefficiency, or potential failures.
W3TSP4418   SDI Test and Record Data
Silt Density Index (SDI) testing performed regularly.
Indicates particulate loading and pretreatment performance.
W3TSP4601   Perform & Replace Prefilter Maintenance per PMI
Replacement of prefilters according to manufacturer PMI schedule.
Maintains upstream filtration integrity and protects DI media tanks.
W3TSP4708   Clean or Sanitize Distribution Loop
Full loop cleaning and sanitization using approved disinfectant processes.
Prevents microbial growth and maintains water purity throughout distribution.

Consumable/Replacement Parts
W2T159701   20" 5Âµm MB CDF PP Plyfm Cartridge
20-inch depth filter cartridge.
5-micron nominal rating.
Multi-bed (MB) CDF polypropylene construction.
Removes particulates prior to DI processing.
W2T850795   UV Lamp (24W, 254nm, Single-End, 4-Pin)
24 watt ultraviolet germicidal lamp.
254 nm wavelength for microbial reduction.
Single end, 4 pin configuration compatible with Evoqua UV housing.
W2T850799   Quartz Sleeve QS535
Quartz protective sleeve for UV lamp insertion.
Maintains lamp isolation from water stream while ensuring UV penetration.
W2T850802   O Ring, LF UV System
OEM O ring seal designed for UV system housing.
Ensures watertight sealing and prevents bypass leakage.
W2T850803   Washer, LF UV Systems
OEM washer component for UV lamp housing assembly.
Maintains correct compression and secure hardware alignment.
W2T918450   20" 0.2Âµm PLT CDF ABS PS1 SIL Cartridge
20 inch, 0.2 micron absolute-rated cartridge.
Designed for final particulate and microbial filtration.
Polymer structured (ABS/PS1 SIL) configuration.
W2T934633   NIL-8 Test Strip (PAA), 50/Test Tube
Test strips for peracetic acid concentration monitoring.
Used during sanitization procedures.
W2T934634   NIL-8 Test Strip (H O ), 50/Test Tube
Hydrogen peroxide concentration test strips.
Supports verification of sanitizer effectiveness.
W2T936744   NIL-8 Sanitizer (1.5 Gallons)
Sanitizing agent used for loop disinfection.
Compatible with Evoqua systems and lab water distribution materials.

DI Media Tanks
W5TDIMB10360FSP   SDI Mixbed 3.6 CF FBGLS STD Pot
Mixed-bed deionization tank (3.6 cubic feet).
Fiberglass standard pot design.
Removes ionic contaminants producing high-purity DI water.
W5TDIRAC0360FSP   SDI React Carbon 3.6 CF FBGLS STD Pot
Activated carbon tank (3.6 cubic feet).
Fiberglass standard pot construction.
Removes chlorine/chloramine and organics upstream of DI beds.
**Please reply to this email by September 24, 2024 @ 10 am est if you are interested in providing these services.**