Comprehensive Fire Alarm and Mass Notification System Replacement at MCAS Cherry Point Building 4213

**Buyer:** Naval Facilities Engineering Systems Command Mid-Atlantic
**Posted:** September 15, 2026
**Respond By:** September 24, 2026
**Identifier:** N400857504546
**NAICS:** 236220, 238210, 562910

This opportunity involves the comprehensive replacement of the fire alarm and mass notification system at Building 4213, Marine Corps Air Station Cherry Point, NC, managed by the Naval Facilities Engineering Systems Command (NAVFAC) Mid-Atlantic.
- Government Buyer:
  - Department of the Navy, Naval Facilities Engineering Command (NAVFAC) Mid-Atlantic, Facilities Engineering & Acquisitions Division
  - Marine Corps Air Station Cherry Point
- Products and Systems Requested:
  - Fire alarm panel and mass notification control unit (addressable, with battery backup and surge protection)
  - VESDA (Very Early Smoke Detection Apparatus) panel and air sampling smoke detection system
  - Manual pull stations, smoke detectors (photoelectric, duct-mounted), carbon monoxide detectors
  - Notification appliances (audible and visual), amplifiers, tone generators, and local operating console
  - Digital Alarm Communicator Transmitter (DACT), interface and control modules, isolation modules
  - Notification power panels, terminal boxes, electrical conduit and wiring, surge protective devices, battery backup
  - Fire alarm system software and site-specific programming
  - Nameplates, keys, and related accessories
- Services Requested:
  - Demolition of the existing fire alarm system and patching/repair of affected areas
  - Testing and commissioning of the new system, including integration with sprinkler and HVAC equipment
  - Lead remediation services for areas with lead-containing paint, following OSHA and EPA regulations
- Unique or Notable Requirements:
  - All systems must comply with NFPA 72 (2025 edition), UFC 3-600-01, and UFC 4-021-01 standards
  - Cybersecurity measures are required for facility-related control systems
  - Strict environmental, safety, quality control, and construction waste management protocols
  - Regulated lead remediation is mandatory due to detected lead-containing paint
- No specific OEMs, part numbers, or quantities are provided; technical details and specifications are referenced in the attachments.

### Description

<p>The work includes fire alarm and mass notification system replacement andsystem modifications, electrical modifications to support fire alarm systems, and incidental related work.</p>

<p>Only the MACC holders listed on the first page of the solicitation may submit a proposal for this project.</p>