Award
Orleans Parish 17493
REMOVAL AND DISPOSAL OF EXISTING PORTLAND CEMENT CONCRETE PA; REMOVAL AND DISPOSAL OF EXISTING SIDEWALK, DRIVEWAY, FO...
Recipient
COMMAND CONSTRUCTION
Award Amount
$20,816,603.20
Ceiling
$20,816,603.20
Awarded
December 31, 2020
Identifier
17493
Description
REMOVAL AND DISPOSAL OF EXISTING PORTLAND CEMENT CONCRETE PA; REMOVAL AND DISPOSAL OF EXISTING SIDEWALK, DRIVEWAY, FOOT LA; REMOVAL AND DISPOSAL OF EXISTING CURB AND GUTTER BOTTOM; REMOVAL AND DISPOSAL OF EXISTING ASPHALTIC CONCRETE PAVEMENT; ROADWAY EXCAVATION; UNSUITABLE SUBGRADE EXCAVATION AND SAND FILLING; GEOTEXTILE FABRIC FOR STABILIZATION; GEOGRID; BASE COURSE; TRAFFIC MAINTENANCE AGGREGATE; 2.5†THICK SUPERPAVE ASPHALTIC CONCRETE WEARING COURSE; 4.5†THICK SUPERPAVE ASPHALTIC CONCRETE BINDER COURSE; COLD PLANING ASPHALTIC PAVEMENT (2.5" AVERAGE THICK); REINFORCED CONCRETE PAVEMENT (8" THICK); STORM DRAIN PIPE (8" PVC); REINFORCED CONCRETE PIPE (12"); REINFORCED CONCRETE PIPE (15"); REINFORCED CONCRETE PIPE (18"); REINFORCED CONCRETE PIPE (24"); RCPA 22 1/2" X 36 1/4" (EQUIV 30"); YARD DRAIN SERVICE LINE (4" PVC); YARD DRAIN SERVICE LINE (6" PVC); REINFORCED CONCRETE WYE - NEW (18" X 15"); POINT REPAIR OF EXISTING DRAINAGE LINE UP TO 10 FEET (10"); POINT REPAIR OF EXISTING DRAINAGE LINE UP TO 10 FEET (12"); POINT REPAIR OF EXISTING DRAINAGE LINE UP TO 10 FEET (15"); POINT REPAIR OF EXISTING DRAINAGE LINE BEYOND 10 FEET (10"); POINT REPAIR OF EXISTING DRAINAGE LINE BEYOND 10 FEET (12"); POINT REPAIR OF EXISTING DRAINAGE LINE BEYOND 10 FEET (15"); NO. 1 STANDARD MANHOLE; NO. 2 STANDARD MANHOLE; CONCRETE SIDEWALK (4" THICK); CONCRETE DRIVEWAY (6" THICK); CONCRETE MOUNTABLE CURB WITH DOWELS; 6" CONCRETE BARRIER CURB WITH DOWELS; CONCRETE MOUNTABLE CURB AND GUTTER BOTTOM; 6" CONCRETE BARRIER CURB & GUTTERBOTTOM OR ROLLING STRIP; PLASTIC PAVEMENT STRIPING (SOLID LINE) (4" WIDTH) (YELLOW/WH; PLASTIC PAVEMENT STRIPING (SOLID LINE) (6" WIDTH) (YELLOW/WH; PLASTIC PAVEMENT STRIPING (BROKEN LINE) (6" WIDTH) (YELLOW/W; SIDEWALK, DRIVEWAY AND CURB SAW CUTTING; PAVEMENT SAW CUTTING ADJACENT TO EXISTING PAVEMENT AND AT PA; REMOVAL OF HANDICAP RAMPS, CURB AND GUTTER, AND CONCRETE SID; HANDICAP RAMPS, CURB AND GUTTER, AND CONCRETE SIDEWALKS AT I; SIDEWALK TRANSITION ADJACENT TO HANDICAPPED RAMPS; SINGLE VERTICAL CATCH BASIN REPAIR OR VERTICAL ADJUSTMENT RE; DOUBLE VERTICAL CATCH BASIN REPAIR OR VERTICAL ADJUSTMENT RE; MOUNTABLE CATCH BASIN GRATE; MANHOLE REPAIR OR VERTICAL ADJUSTMENT UP TO 6" REUSING EXIST; MANHOLE REPAIR OR VERTICAL ADJUSTMENT OVER 6" REUSING EXISTI; NEW WATER VALVE MANHOLE (4" THROUGH 12" VALVES); 8" PVC NEW WATER MAIN WITH MAIN LINE FITTINGS; 8" DUCTILE IRON NEW WATER MAIN WITH MAIN LINE FITTINGS; 12" PVC NEW WATER MAIN WITH MAIN LINE FITTINGS; NEW 6" VALVE; NEW 8" VALVE; NEW FIRE HYDRANT; REPLACE 5/8" TO 1'' WATER HOUSE CONNECTION WITH 1'' WATER; REPLACE 1-1/2" WATER HOUSE CONNECITON (FROM MAIN TO METER); REPLACE EXISTING 2" WATER HOUSE CONNECTION (FROM MAIN TO MET; 8" WATER LINE OFFSET UP TO 24"; 12†WATER LINE OFFSET UP TO 24â€; REMOVE MUD AND DEBRIS FROM INSIDE OF WATER METER BOX; ADJUST COMPLETE WATER METER BOX TO GRADE; REPLACE BROKEN WATER METER BOX (5/8") TO (1"); PLUG EXISTING WATER MAIN 4" THROUGH 12" AND FILL WITH FLOWAB; REPAIR WATER MAIN WITH FULL CIRCLE CLAMP (PIPE SIZE 4" - 8"); REPAIR WATER MAIN WITH FULL CIRCLE CLAMP (PIPE SIZE 12" - 36; REPAIR WATER MAIN BY REMOVE AND REPLACE - MIN 4', MAX 10' (P; REPAIR WATER MAIN BY REMOVE AND REPLACE BEYOND 10', MAX 18'; REMOVAL AND DISPOSAL OF EXISTING CURB (CONCRETE, ASPHALT, BR; INSTALL SEWER MAIN (8" AT 6.1' - 8.0'); INSTALL SEWER MAIN (8" AT 8.1' - 10.0'); INSTALL SEWER MAIN (10" AT 8.1' - 10.0'); SEWER POINT REPAIR UP TO 10 FEET (8" AT 0' - 6.0'); REPLACE EXISTING SEWER H.C. FROM EXISTING OR NEW MAIN PROPER; REPLACE EXISTING SEWER H.C. BEYOND BACK OF CURB; PIPE LINER (CIPP, 8"); CUT LINER TO RESTORE EXISTING SEWER HOUSE CONNCECTION (6", C; MANHOLE COVER; MANHOLE FRAME; SEWER MAIN LINE CLEANING (8" - 13"); SEWER MAIN LINE CLEANING (15"); SEWER MAIN LINE CCTV INSPECTION (8"- 12"); SEWER MAIN LINE CCTV INSPECTION (15"); SODDING; SEWER POINT REPAIR UP TO 10 FEET (8" AT 6.1 TO 8.0); SEWER POINT REPAIR UP TO 10 FEET (8" AT 8.1 TO 10.0); SEWER POINT REPAIR UP TO 10 FEET (8" AT 10.1 TO 12.0); SEWER POINT REPAIR BEYOND 10 FEET (8" AT 8.1 TO 10.0); MANHOLE REHAB, PARTYIAL DEPTH (2") CEMENT LINER; MANHOLE REHAB, FULL DEPTH CEMENT LINER; INSTALL SEWER MAIN (8" AT 10.1 TO 12.0); Exploratory Excavations; Adjust Sewer House Connections; Change out Fiberglass Grate to Cast Iron Rollover Grates; Sewer Point Repair up to 12 feet (15" at 10.1 to12_; Superpave Asphaltic Concrete Binder Course for Composite Roa; Roadway Excavation; Sewer Point Repair up to 10 feet (8" at 8.1 to 10); REMOVAL AND DISPOSAL OF EXISTING CURN AND GUTTER BOTTOM; REMOVAL AND DISPOSAL OF EXISTING ASPHLIC CONCRETE PAVEMENT; REINFORCED CONCRETE PIPE (18")%09; NO. 2 STANDARD MANHOLE%09; CONCRETE MOUNTABLE CURB AND GUTTER BOTTOM%09; REPLACE EXISTING SEWER H.C. BEYOND BACK OF CURB%09; MOUNTABLE CATCH BASIN GRATE%09; MANHOLE COVER%09; MANHOLE FRAME%09; DRAINAGE SIPHON%09; 4.5" THICK SUPERPAVE ASPHALTIC CONCRETE BINDER COURSE; 12" DUCTILE IRON NEW WATER MAIN WITH MAIN LINE FITTINGS; BY-PASS PUMPING SEWER; 6" PERFORATED SOCKED UNDERDRAIN; SEWER HEAVY CLEANING; INSTALL SEWER MAIN (8" AT 10.1' - 12.0'_); INSTALL SEWER HOUSE CONNECTION (MAIN TO PROPERTY LINE); STEEL SHEETING; STEEL MANHOLE BRACING SYSTEM; WELL POINTING; BYPASS PUMPING; VIBRATION MONITORING; 16" DUCTILE IRON NEW WATER MAIN WITH LINE FITTINGS; 16" WATER LINE OFFSET; SEWER POINT REPAIR BEYOND 10 FEET (8" AT 10.1' - 12.0'); REMOVE PALM TREE @ 7939 HICKMAN STREE; FORCE ACCOUNT EXPLORATORY EXCAVATION; SINGLE OR DOUBLE MOUNTABLE CATCH BASIN FRAME; SEWER HEAVY MAIN LINE CLEANING ON MARYWOOD COURT; SEWER MAIN LINE CCTV INSPECTION ON MARYWOOD COURT; ELECTRICAL WARNING TAB; ELECTRICAL PULL BOXES ON DANUBE; UNSUITABLE SUBGRADE EXCAVATON AND SAND FILLING; 12ââ%E2%80%9A¬Â%C2%9D WATER LINE OFFSET UP TO 24ââ%E2%80%9; ADDITIONAL LABOR AND MATERIALS FOR MORRISON CANAL WATER LINE; ADDITIONAL LABOR AND MATERIALS FOR TIE-IN OF 8' WATER LINE A; STONE BASE AND FABRIC UNDER SIDEWALK (PER P&P SIDEWALK DETAI; NEW 12" VALVE; REPAIR OF WATER LINE BLOW OUT 7600 MERCIER; REMOVAL OF DEBRIS ON MORRISON AT ANNE MARIE CT; REPAIR OF WATER LINE BLOWOUT ON 7700 BL OF HICKMAN; C202(52) (C) B.2.2 PC 18; C202(52) (I) B.1.1 PC 18; CF-375 A.1.1 PC 18; C203(60) B.2.2 PC 18